13
Step 1
Have all transmitters which are to operate the system at hand� Then, turn the ignition “on”�
If the Unauthorized Transmitter Alert feature is on, programming a transmitter to the
system will activate the “UTA” warning and the extended Status Light indication�
For the next 48 hours, the horn will sound a brief series of chirps every time the
vehicle’s ignition key is turned on�
Step 3
Press the “
lock
” button (press “
start
” button for RS-250-EDPB) on each remaining trans-
mitter one at a time. The system will chirp the horn once to confirm that each was learned. The
transmitter’s other three button’s functions will automatically be assigned when the “
lock
” button is
learned� If a code is not received within a 10 second period, the learning process will automati-
cally terminate, as indicated by another horn honk�
Step 2
Within 5 seconds of turning on the ignition, press the Valet Switch 5 times� The horn will
briefly sound, confirming that for the next 10 seconds the system is ready to learn a transmitter/
controller code� To enter a code, simply press and release the “
lock
” button. When the first code
is learned all existing stored codes will be erased�
Special Programming procedure to turn On the UTA feature:
Using this method to program
transmitters or optional controllers, and to turn on the Unauthorized Transmitter Alert feature�
Follow the same steps as the Standard Programming, but on any transmitter/controller being
programmed instead of pressing the “
lock
” button, press the “
lock
” and the “
unlock
” buttons
together� This action turns
on
the Unauthorized Transmitter Alert feature and at the same time
programs the transmitter or controller to operate the system�
Standard Programming:
Using this method to program additional or replacement transmitters
does not turn on or otherwise affect the Unauthorized Transmitter Alert (UTA) feature�
Once the Unauthorized Transmitter Alert feature is turned on, the warning will sound for 48
hours after any transmitter programming, including the programming session which was used to
turn it on� This feature can only be turned off again by sending the system back to Omega for a
reset�
Programming Transmitters