Excalibur Water Systems EWR 5075 Installation, Operation & Service Manual Download Page 14

 

Problem Possible 

Cause

Solution

High Total Dissolved Solids 
(TDS) in the Product Water 
(continued) 

The Product Water and Drain 
Water lines are reversed. 

Correct plumbing. 

No drain flow, Reverse Osmosis 
Drain Restrictor is clogged. 

Clear or replace Reverse Osmosis 
Drain Restrictor. 

The Reverse Osmosis ASO Valve 
is not closing. 

Repair or replace the Reverse 
Osmosis ASO Valve Components. 

New In-Line or Activated Carbon 
Pre-filter not rinsed completely. 

Flush with several full tanks of 
Product Water. 

The Reverse Osmosis Feed Water 
TDS has increased. 

An increase in Reverse Osmosis 
Feed Water TDS will give a 
corresponding increase in Product 
Water TDS. 

Tastes and odors in the Reverse 
Osmosis Product Water 

The In-Line or Activated Carbon 
Pre-filter is exhausted. 

Replace Reverse Osmosis Filters. 

There is foreign matter in the 
Reverse Osmosis  Holding Tank. 

Clean, flush and sanitize the 
system. Replace the filters. 

The Product Water and Reverse 
Osmosis Drain Water lines are 
reversed. 

Correct plumbing. 

Dissolved gassed in the Reverse 
Osmosis Feed Water. 

Pre-treat Reverse Osmosis Feed 
Water to remove dissolved gasses.  

Increase in Product Water TDS. 

See high TDS in the Reverse 
Osmosis Product Water section. 

Reverse Osmosis Drain Water 
overflows at the Air Gap Faucet 

Drain tubing is clogged. 

Clear tubing. 

Drain clamp hole is misaligned. 

Align with hole in the drain pipe. 

Excessive drain flow rate. 

Replace Reverse Osmosis Drain 
Restrictor. 

Reverse Osmosis Faucet leaks 
or drips 

Leaks from spout. 

Adjust Reverse Osmosis Faucet by 
turning the tee bar just below the 
handle to provide a small amount 
of free play in handle when shut off. 
O-rings are bad, repair or replace 
faucet. 

Leaks from base of the delivery 
tube. 

O-ring is bad, replace O-ring. 

Leaks from beneath the handle. 

O-rings are bad. Repair or replace 
the faucet. 

Reverse Osmosis Fitting leaks in 
general 

Close the Reverse Osmosis Feed Water Ball  Valve and relieve pressure 
before disconnecting any tubing or replacing any fitting. Before replacing 
a fitting, re-cut the tubing and re-insert into the fitting to see if that solves 
the leak. If pipe threads are leaking, remove and re-tape with Teflon tape. 

 
 
 
 
 
 
 
 
 
 
 
 
 

12 

Summary of Contents for EWR 5075

Page 1: ...Model EWR 5075 INSTALLATION OPERATION SERVICE MANUAL Barrie Ontario Canada www excaliburwater com REVERSE OSMOSIS DRINKING WATER SYSTEMS...

Page 2: ...se Osmosis Water Quality 10 REVERSE OSMOSIS TROUBLESHOOTING GUIDE 11 12 CAUTION The Centers for Disease Control and Prevention CDC and the Environmental Protection Agency EPA have issued guidance to p...

Page 3: ...f these pores typically 800 1200 square meters per gram of carbon gives the Reverse Osmosis carbon very good adsorption sites for substances that contribute to tastes and odours The Reverse Osmosis ca...

Page 4: ...Carbon Post Filter 2 Filter Housings with O Rings 12 Other items necessary for Reverse Osmosis installation may include wood screws or machine screws and nuts for mounting the manifold or concrete anc...

Page 5: ...3 BALL...

Page 6: ...nd an open area beneath the Reverse Osmosis faucet under the sink for attaching product and Reverse Osmosis drain tubing are considerations A 2 diameter flat surface is required above and below the Re...

Page 7: ...component position 2c Drilling a counter top NOTE The counter top must be less than 2 thick Treat ceramic tiles as porcelain until the tile is penetrated then use the carbide tipped metal cutter Form...

Page 8: ...Reverse Osmosis to a hot water feed line Water over 100 F may cause permanent damage to the Reverse Osmosis Membrane Refer to Fig 3 page 8 1 Shut off the water supply and drain the line from the Reve...

Page 9: ...er is flowing to drain Refer to Fig 4 below To connect the Drain Tubing install the Compression Nut and the Brass Insert Insert the tubing into the Drain Clamp and tighten the Compression Nut Choose t...

Page 10: ...y fine black powder from the In Line Activated Carbon Post Filter to be rinsed out This is normal for the first tank of water or after the In line filter is changed 1 Check the Reverse Osmosis tank pr...

Page 11: ...ve the wrapping and install the Reverse Osmosis Activated Carbon Pre filter Firmly tighten the Reverse Osmosis Housing hand tight only Disconnect the Reverse Osmosis tubing that runs from the Reverse...

Page 12: ...m or Milligrams per Liter mg l of Total Dissolved Solids TDS Although technically they are not exactly equal in most discussions ppm mg l Reverse Osmosis Membranes are rated by the amount of dissolved...

Page 13: ...mosis Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air pre charge in the Reverse Osmosis Holding Tank is too low Empty water from Reverse Osmosis Holding Tank...

Page 14: ...Correct plumbing Dissolved gassed in the Reverse Osmosis Feed Water Pre treat Reverse Osmosis Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Reverse Osmosis P...

Page 15: ...e above warranties are effective provided the Reverse Osmosis System is operated at water pressures not exceeding 125psi and at water temperatures not exceeding 120 F also provided that the RO system...