EXAGATE SYSGuard 3001 Quick Installation Manual Download Page 4

 

 

 

 

Operational Properties 

 
 

Power Supply Voltage 

 

 

10,5 - 14,4 VDC typical 12 VDC 

 
 

Power Consumption 

 

 

0,22 - 0,36 A typical 0,24 A 

 

 

 

 

 

 

2,64 - 4,62 W typical 2,88 W 

 
 

Operational Temprature Range 

 

-10 +70 

o

 
 

Operational Humidity Range 

 

0 - 85 % Rh 

 
 

Storage Temprature Range 

 

-40 +85 

o

 
 

Storage Humidity Range   

 

0 - 90 % Rh 

 

Physical Properties 

 

Dimensions (H x W x D)   

 

44,14 x 480 x 101  

mm 

 

 

1,73 x  18,89 x 3,97  

inches 

 

 

Color 

 

 

 

 

Black 

 

Internal Temperature & Humidity Sensor 

 
 

Temperature Measurement Range   

-10 +70 

 
 

Temperature Measurement Tolerance 

+/- 0,4 

 
 

Temperature Measurement Resolution 

0,1 

 

 
 

Humidity Measurement Range 

 

0 - 85 % Rh 

 
 

Humidity Measurement Tolerance   

+/-3 % Rh 

 
 

Humidity Measurement Resolution   

%0,1 Rh 

 
 

Maximum Distance from Main Unit   

3 m 

 

Inputs & Outputs 

 

 

Analog / Water Sensor Port 

 

Dry Contact Input 

 

Relay Output 

 

 

4  units   

 

 

 

16 units  

 

 

4 units 

 

Analog resolution 10bit 

 

 

5-12 VDC 

 

 

NO / NC 

 

Voltage Range 0-5 VDC   

 

Isolated  

 

 

Max. 5A 

 

 

 

RS232 (2 Units)   

 

USB Port (2 Units) 

 

Ethernet Port (1 Unit) 

 

ExaBus Port (16 Units) 

 

Slave Power Input (1 Unit)  

External Power Input (max.=1A) 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SYSGuard 3001

Page 1: ...SYSGuard 3001 Quick Installation Guide ...

Page 2: ...ssignment Mode Step 2 Main unit is equipped with default IP address 192 168 1 141 For the first access to the device a PC must be used to access the main unit and devices should be connected to the same network Your PC should have a static IP in order to access SYSGuard 3001 You can carry out these settings in TCP IP Settings sections of Local Area Network Connection options Step 3 Write 192 168 1...

Page 3: ...DY MENU X1 SET X4 X7 T H X2 X3 X5 X6 X8 X15 X9 X10 X13 X11 X16 X14 X12 MAIN POWER 12V DC SLAVE POWER 12V DC 12V DC 12V DC GND GND POWER OUTPUTS DRY CONTACT INPUTS ANALOG W DETECT INPUTS RELAY OUTPUTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 4 3 NC NO COM RELAY OUT 1 NC NO COM RELAY OUT 2 NC NO COM RELAY OUT 3 NC NO COM RELAY OUT 4 EKSAGATE ELEKTRONIK MUHENDISLIK VE BILGİSAYAR SAN TİC A Ş Sehit A...

Page 4: ...ernal Temperature Humidity Sensor Temperature Measurement Range 10 70 Temperature Measurement Tolerance 0 4 Temperature Measurement Resolution 0 1 Humidity Measurement Range 0 85 Rh Humidity Measurement Tolerance 3 Rh Humidity Measurement Resolution 0 1 Rh Maximum Distance from Main Unit 3 m Inputs Outputs Analog Water Sensor Port Dry Contact Input Relay Output 4 units 16 units 4 units Analog reso...

Page 5: ...ing System P 18 89 in 480 mm 1 73 in 44 14 mm 3 97 in 101 mm 2 62 in 66 6 mm 0 24 in 6 30 mm 0 38 in 9 90 mm 16 92 in 430 mm Sample Connection Diagrams SYSGUARD 3001 Environment Monitoring System COM 1 USB COM 2 LAN READY MENU SET T H C GSM MODEM ...

Page 6: ...14 15 16 12V DC 12V DC GND GND POWER OUTPUTS TEST DO NOT PAINT X X X X 5 6 4 2 ANALOG W DETECT INPUTS 1 2 4 3 RELAY OUTPUTS NC NO COM RELAY OUT 1 NC NO COM RELAY OUT 2 NC NO COM RELAY OUT 3 NC NO COM RELAY OUT 4 AIR CONDITIONER CONTACTOR IF NECESSARY 1 ...

Page 7: ...Installation Notes ...

Page 8: ...with no charge to owner Conditions Void of Warranty Damages on unit cable or screen Defections due to electrical wiring and or city network Interference to unit by non authorized staff Any problems caused by act of nature Misusage of unit stated by the user manual Removal or destruction of serial number warranty labels Any kind of modifications Instructions in this QIG are in abstract essence For ...

Reviews: