5.
The current contents of the CTS’s program memories are erased
and replaced with the validated microcode from the buffer.
CAUTION
Do not power off or reset the CTS during this step. Wait until
the following step (step 6) is finished. The tape will be ejected
when the load process is complete.
If a hardware or power failure occurs during this step, the
CTS may not be able to operate. If this occurs, use the CTS
Monitor program to reload microcode (from a *.BIN file)
through a serial cable attached to the Monitor port. (See the
CTS Monitor User’s Guide for complete instructions.)
6.
When the new microcode has been loaded successfully, the CTS
performs a full power-on reset and self-test (POST). During the
first part of POST, all LEDs will be on. As POST completes, the
top amber LED will stay on and the bottom LED will flash slow
and then fast. The load tape is ejected after approximately 15
seconds into the 32-second self-test.
If the CTS Monitor program is running and the load was
successful, the following message will appear:
L: Load of new code is successful!
If the load fails, the top amber LED will flash. If the CTS Monitor
program is running, the following message will be displayed:
K: Load of new code failed!
If a failure occurs, retry the operation with another tape or use
the CTS Monitor program to reload microcode (from a *.BIN
file) through a serial cable attached to the Monitor port. (See the
CTS Monitor User’s Guide for complete instructions.)
3
-
8
510702
3 Loading New Microcode from Tape
Summary of Contents for EXB-8205
Page 1: ...510702 000 0 538 0 838 PP 7DSH ULYHV 0DLQWHQDQFH ...
Page 2: ...EXB 8205 EXB 8505 8mm Cartridge Tape Subsystems Maintenance ...
Page 5: ...Notes iv 510702 ...
Page 9: ...viii 510702 ...
Page 29: ...Notes 1 16 510702 1 Before You Begin ...
Page 43: ...Notes 3 10 510702 3 Loading New Microcode from Tape ...
Page 101: ...Notes I 4 510702 Index ...