Symptom
Cause
Corrective Action
The fl ame effect will
not start.
Mains plug is not plugged in.
Low water level.
Low voltage connector not connected prop-
erly. (See Fig.10)
Check plug is connected to wall socket cor-
rectly.
Check that the water tank is full and there is
water in the sump.
Check that the connector is inserted correct-
ly. (See Fig.10)
The fl ame effect is too
low.
Flame effect control knob is set too low.
The Metal Disc in the transducer might be
dirty
The wire from the Transducer Unit is sitting
over the metal disc
Increase level of fl ame by pressing
on
your remote or receiver
Clean the Metal Disc with a soft brush. See
‘Maintenance.’ for a step by step procedure.
Direct the wire to the back of the sump and
make sure it sits into the side slot exiting the
sump.
Unpleasant smell
when unit is used.
Dirty or stale water.
Using unfi ltered tap water.
Clean the unit as described under mainte-
nance.
Use only fi ltered tap water.
The fl ame effect has
too much smoke.
Flame effect setting is too high.
Turn down the fl ame effect. Give the fl ame
generator some time to adjust to the new
setting.
Troubleshooting
14