Machine description
– quick overview
Machine control
– Operating elements
22
099-000237-EW501
25.04.2019
4.3.1
Machine control
– Concealed operating elements
Figure 4-4
Item Symbol
Description
0
1
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
2
Signal light, wire feeder start delay
Setting range 0.0 s to 20.0 s
3
Signal light, wire feed speed of main program (P
A
)
4
sec
Signal light, duration of main program P
A
Setting range 0.1 s to 20.0 s (0.1 s increments).
Used e.g. in connection with the super pulse function
5
Signal light, wire feed speed of reduced main program (P
B
)
6
Signal light, duration of reduced main program P
B
Setting range: 0.1 s to 20.0 s (0.1 s increments).
Use in conjunction with the SuperPulse function or tack welding.
7
Signal light, wire return
Setting range from 0.0 mm to 50.0 mm
8
Super-
puls
Signal lamp, super pulse function
Lights up when the super pulse function is active.
9
Push-button, wire inching
Potential- and gas-free inching of the wire electrode through the hose package to the
welding torch
> see 5.1.11.3 chapter
.
10
Push-button gas test / rinse hose package
> see 5.1.12 chapter