Design and function
Menus and sub-menus on the machine control
099-000120-EW501
26.07.2011
75
Display Setting/selection
Error output to automated welding interface, contact SYN_A
off
AC synchronisation or hot wire (factory setting)
FSn
Error signal, negative logic
FSP
Error signal, positive logic
AvC
AVC (Arc voltage control) connection
Automation menu
Fast take-over of control voltage (automation)
• on = function on
• off = function off (factory setting)
Orbital welding
• off = off (ex works)
• on = on
Orbital welding
Correction value for orbital current
Service menu
Modifications to the service menu may only be carried out by authorised maintenance
staff!
Reset (reset to factory settings)
• off = aus (factory setting)
• CFG = Reset the values in the machine configuration menu
• CPL = Complete reset of all values and settings
The reset is performed when leaving the menu (EXIT).
Software version query (example)
07= System
bus
ID
02c0= Version
number
System bus ID and version number are separated by a dot.