Design and function
Menus and sub-menus on the machine control
74
099-000120-EW501
26.07.2011
Display Setting/selection
Exit the menu
Exit
Torch configuration menu
Set welding torch functions
Torch mode
• Modes 1-6: with tapping function (factory setting 1)
• Modes 11-16: without tapping function
Setting the first increment
Setting: 1 to 20 (factory setting 1)
Up-/Down speed (not available in modes 4 and 14)
Increase value
= rapid current change (factory setting 10)
Reduce value
= slow current change
Machine configuration
Settings for machine functions and parameter display
Welding current display (ignition, secondary, end and hotstart currents)
• Pro = welding current display as a percentage of the main current (factory setting)
• Abs = absolute welding current display
Non-latched operation (C version)
• on = on
• off = off (factory setting)
Power display switching (MMA)
• on = actual value display
• off = setpoint value display (factory setting)
spotMatic
Variation of operation mode spotArc, ignition with workpiece contact
• on = on
• off = off (factory setting)
Ramp function Remote control RTF 1
The ramp function can be switched on and off
Pulses in the upslope and downslope phases
The function can be switched on or off
Torch cooling mode
• AUt = automatic operation (ex works)
• on = permanently switched on
• off = permanently switched off
Expert menu
AC mean value controller
• on = on (factory setting)
• off = off
Switching option for welding current potential (dc+) with TIG DC
• off = Select option for TIG DC+ is blocked (factory setting). Serves to protect the
tungsten electrode from being destroyed.
• on = Polarity can be selected freely
Reconditioning pulse (spherical cap stability)
• on = function on (factory setting)
• off = function off
activArc voltage measuring
• on = function on (factory setting)
• off = function off