Design and function
Menus and sub-menus on the machine control
099-000124-EW501
29.07.2011
61
Display Setting/selection
Orbital welding
Correction value for orbital current
Service menu
Modifications to the service menu may only be carried out by authorised maintenance
staff!
Reset (reset to factory settings)
• off = aus (factory setting)
• CFG = Reset the values in the machine configuration menu
• CPL = Complete reset of all values and settings
The reset is performed when leaving the menu (EXIT).
Software version query (example)
07=
System bus ID
02c0= Version
number
System bus ID and version number are separated by a dot.