Technical data
Performance data
099-005649-EW501
19.11.2020
57
8.2 Performance data
8.2.1 Taurus XQ 350 Synergic D
MIG/MAG
MMA
TIG
Welding current (I
2
)
5 A to 350 A
Welding voltage according to standard (U
2
) 14,3 V to 31,5 V
20,2 V to 34,0 V
10,2 V to 24,0 V
Duty cycle DC at 40° C
[1]
350 A (100%)
Mains voltage
[2]
3 x 380-400 V / 3 x 440-460 V / 3 x 480-500 V
Frequency
50/60 Hz
Tolerance / mains fuse
[3]
380-400 V
-25 % to+20 % / 3 x 25 A
440-460 V
-25 % to+15 % / 3 x 20 A
460-500 V
-25 % to+10 % / 3 x 20 A
Open circuit voltage (U
0
)
82 V (380-400 V)
94 V (440-460 V)
102 V (460-500 V)
max. Connected load (S
1
)
gas cooled (F06G)
14,3 kVA
15,4 kVA
10,9 kVA
water cooled (F06W)
14,7 kVA
11,3 kVA
water cooled, Reinforced (F06WRF)
14,9 kVA
11,5 kVA
Generator rating (Rec.)
21 kVA
Power consumption P
0
[4]
25 W
Maximum mains impedance (@PCC)
[5]
107 mOhm
Cos φ / efficiency
0,99 / 90 %
Protection class / Overvoltage category
Ⅰ
/
Ⅲ
Contamination level / Insulation class
3 / H
protection classification / Residual current
circuit breaker
IP 23 / Type B (recommended)
Noise level
[6]
<70 dB(A)
Ambient temperature
[7]
-25 °C to +40 °C
Machine cooling / Torch cooling
Fan (AF) /
gas or water
Mains connection cable
H07RN-F4G6
Workpiece lead (min.) / EMC class
70 mm
2
/ A
Safety marking
/
/
Standards used
See declaration of conformity (appliance documents)
[1]
Load cycle: 10 min. (60 % DC
≙
6 min. welding, 4 min. pause)
[2]
Multi-voltage device - Adjusting the power source to the mains voltage
[3]
Safety fuses are recommended DIAZED xxA gG. When using automatic cutouts, the "C" trigger
characteristic must be used.
[4]
Power in idle mode without wire feeder.
[5]
This welding equipment does not comply with IEC 61000-3-12. When connecting a welding machine
to a public low-voltage supply system, the manufacturer or operator has to consult the electricity
utilities to make sure the welding machine may be connected.
[6]
Noise level during idle mode and operation under standard load according to IEC 60974
‑
1 at the
maximum operating point.
[7]
Ambient temperature dependent on coolant! Observe coolant temperature range!