background image

 

Design and function 

Transport and installation 

 

099-005649-EW501 

19.11.2020

 

25

 

 

5.1.8  Stray welding currents 

 

 

 WARNING 

 

Risk of injury due to stray welding currents! 

Stray welding currents can destroy protective earth conductors, damage machines and 

electronic devices and cause overheating of components, leading to fire. 

•  Check that all welding current connections are firmly secured and electrical connections are 

in perfect condition. 

•  Set up, attach or suspend all conductive power source components such as casing, trans-

port vehicles and crane frames so they are insulated. 

•  Do not place any other electronic devices such as drills or angle grinders on the power 

source, transport vehicle or crane frames unless they are insulated. 

•  Always put welding torches and electrode holders on an insulated surface when they are 

not in use. 

 

 

Figure 5-6 

 

Summary of Contents for Taurus XQ 350 Synergic D

Page 1: ...perating instructions EN Power source Taurus XQ 350 Synergic D Taurus XQ 400 Synergic D Taurus XQ 500 Synergic D Taurus XQ 600 Synergic D 099 005649 EW501 Observe additional system documents 19 11 202...

Page 2: ...authorised sales partners can be found at www ewm group com en specialist dealers Liability relating to the operation of this equipment is restricted solely to the function of the equipment No other f...

Page 3: ...orkpiece lead general 21 5 1 6 Welding torch cooling system 22 5 1 6 1 Functional characteristics 22 5 1 6 2 Permitted torch coolant 22 5 1 6 3 Maximal hose package length 22 5 1 6 4 Adding coolant 23...

Page 4: ...t inspection and testing during operation 47 6 4 Disposing of equipment 47 7 Rectifying faults 48 7 1 Error messages power source 48 7 2 Warnings 51 7 3 Checklist for rectifying faults 52 7 4 Vent coo...

Page 5: ...s and even fatal injuries Safety notes include the WARNING keyword in the heading with a general warning sym bol The hazard is also highlighted using a symbol in the page margin CAUTION Working or ope...

Page 6: ...tch off machine Release Switch on machine Press and hold Switch Incorrect Invalid Turn Correct Valid Numerical value adjustable Input Signal light lights up in green Navigation Signal light flashes gr...

Page 7: ...Prevention Regulation BVG D1 formerly VBG 15 or country specific regulations Before commencing arc welding a test must verify that the equipment cannot exceed the maximum permitted open circuit volta...

Page 8: ...sion risk Apparently harmless substances in closed containers may generate excessive pressure when heated Move containers with inflammable or explosive liquids away from the working area Never heat ex...

Page 9: ...specified in the standard The user is responsible for any interference caused by welding In order to evaluate any possible problems with electromagnetic compatibility in the surrounding area the user...

Page 10: ...placement parts etc from our range of products Only insert and lock accessory components into the relevant connection socket when the ma chine is switched off Requirements for connection to the public...

Page 11: ...on or connection points can heat up significantly during operation water cooled version When opening the coolant circuit escaping coolant may cause scalding Open the coolant circuit only when the powe...

Page 12: ...suitable wire feed unit system component is required in order to operate the welding machine The following system components can be combined Titan XQ 350 600 puls D Phoenix XQ 350 600 puls D Taurus X...

Page 13: ...For this purpose appropriate national or international regulations must be followed The power source must not be placed in the danger zone 3 3 4 Service documents spare parts and circuit diagrams WARN...

Page 14: ...other parts of these instructions Read and observe the operating instructions for all system components especially the safety instructions The illustration shows a general example of a welding system...

Page 15: ...sion stages of the device series XQ Type Figure Transport properties Torch cooling Wheel kit narrow track wit hout cylinder bracket Pallet bottom without cylinder bracket Wheel kit single cylinder bra...

Page 16: ...uick overview Front view side view from the right 16 099 005649 EW501 19 11 2020 4 2 Front view side view from the right Figure 4 2 Item Symbol Description 0 1 WiFi antenna Factory fit option version...

Page 17: ...th a foot lock 12 Inlet opening for cooling air torch cooling Dirt filter can be retrofitted 13 Wheels fixed castors 14 Lifting lug see 5 1 1 chapter 15 Intermediate hose package strain relief see 5 1...

Page 18: ...ew side view from left 18 099 005649 EW501 19 11 2020 4 3 Rear view side view from left Figure 4 3 Item Symbol Description 0 1 Securing elements for shielding gas cylinder strap chain 2 Cooling air in...

Page 19: ...Individual mounting option for accessories and options 10 Intermediate hose package strain relief see 5 1 9 chapter 11 Mains connection cable see 5 1 11 chapter 12 Outlet opening cooling air torch coo...

Page 20: ...em component has to be lifted separately Remove any supply leads and accessories before lifting by crane e g hose package wire spool shielding gas cylinder toolbox wire feeder remote control etc Prope...

Page 21: ...3 2 Transport and storage Storage in a closed room temperature range of the ambient air 30 C to 70 C 22 F to 158 F 1 Relative humidity up to 90 at 20 C 68 F 1 Ambient temperature dependent on coolant...

Page 22: ...s in the machine adjustable depending on control system are stored for monitoring and control of the cooling system If the cooling system is faulty or overloaded an error message appears and the weldi...

Page 23: ...lant in the coolant tank than the minimum required you may need to vent the coolant circuit In this case the welding machine will automatically shut down the coolant pump and signal an error see 7 4 c...

Page 24: ...ith HF igniter TIG for as long as pos sible in parallel with a distance of 20 cm to avoid HF sparkover Always keep a distance of at least 20 cm to leads of other power sources to avoid interferences A...

Page 25: ...heck that all welding current connections are firmly secured and electrical connections are in perfect condition Set up attach or suspend all conductive power source components such as casing trans po...

Page 26: ...e connection socket Wire feeder control cable connection 4 Intermediate hose package strain relief see 5 1 9 chapter 5 Connection socket welding current Standard MIG MAG welding intermediate hose pack...

Page 27: ...coolant supply Some wire electrodes e g self shielding cored wire are welded using negative polarity In this case the welding current lead should be connected to the welding current socket and the wor...

Page 28: ...g gas cylinder onto the receptacle of the shielding gas cy linder and secure with both safety belts provided on the device as stan dard Belts must be tight Do not attach any element to the shielding g...

Page 29: ...as stipulated in the operating in structions The network created must be suitable for operating machines according to pro tection class I The welding power source is equipped with an internal clamp de...

Page 30: ...up Reconnect operating voltage plug printed circuit board VB xx0 to the corresponding voltage range of the supply voltage 380V 400V ex works Hook housing cover from above into the aluminium continuous...

Page 31: ...ices This time can take from several seconds to several minutes e g for the system components interconnected for the first time During this start phase the system components will display the controlle...

Page 32: ...ion 32 099 005649 EW501 19 11 2020 5 1 13 Protective flap welding machine control Figure 5 14 Open the protective cap Apply slight pressure on the left connecting bridge figure until the flap s fasten...

Page 33: ...welding current connection socket and lock Some wire electrodes e g self shielding cored wire are welded using negative polarity In this case the welding current lead should be connected to the weldin...

Page 34: ...he shielding gas The push button is generally found near a wire feeder Shielding gas flows for around 25 seconds or until the button is pressed again If the shielding gas setting is too low or too hig...

Page 35: ...d work pieces Figure 5 17 Item Symbol Description 0 1 Connection socket welding current 2 Connection socket welding current 3 Workpiece 4 Electrode holder Insert the electrode holder plug and workpiec...

Page 36: ...will not shut down Remove jumper 1 on the corresponding control board to be done only by qualified service personnel These accessory components can be retrofitted as an option see 9 chapter Pin Input...

Page 37: ...between the PC and the welding machine The connection must only be made using the cables supplied do not use any additional ex tension cables PC300 Net welding parameter software Set all welding param...

Page 38: ...welding parameters Recording documentation Monitoring of welding parameters Maintenance Calculations WPS management Welder management xButton management Component management The functionality of the s...

Page 39: ...ne must not be operated again until it has been repaired and a new test has been carried out As a rule contact your specialised dealer i e the supplier of the machine with respect to all servicing mat...

Page 40: ...49 EW501 19 11 2020 6 2 Explanation of icons Person Welder operator Service staff expert qualified person Test Visual inspection Functional check Period interval One shift operation Multi shift operat...

Page 41: ...packages secured with strain relief Checking all supply lines and their connections pipes hoses hose packages for damage or leaks Checking the welding system for damage to the housing Transport eleme...

Page 42: ...pressed air depending on the level of soiling Figure 6 1 Two dirt filters option for retrofitting can be installed on the machine One at the air inlet of the power unit inverter and one at the air inl...

Page 43: ...ine and disconnect the mains plug Position a suitable collecting container under the drain plug of the coolant tank Unscrew the drain plug of the coolant tank remove the tank cap to ventilate Figure 6...

Page 44: ...19 11 2020 Figure 6 5 Insert the cleaned filter screen into the filler neck and screw the drain plug with seal back into the tank Fill the tank with original EWM coolant up to the maximum level After...

Page 45: ...the side panel Remove the side panel from the system lift up and sidewards Use only compressed air free of water and oil Do not blow on electronic components directly The ma chine fans may over rev du...

Page 46: ...nnect the mains plug Remove the screws of the side panels and the grille at the rear Remove side panels lift up and to the side Remove louvre remove downwards and to the back Use only compressed air f...

Page 47: ...EU on Waste of Electrical and Electronic Equipment used electric and electronic equipment may no longer be placed in unsorted municipal waste It must be collected separately The symbol depicting a was...

Page 48: ...system the error with the lowest error number Err is displayed If this error is corrected the next higher error number appears This process is repeated until all errors have been resolved Categories l...

Page 49: ...or defective Check fan clean or replace Air inlet or outlet blocked Check air inlet and outlet 32 Error I 0 3 Inform Service 33 Error UIST 3 Short circuit in welding circuit before welding Eliminate s...

Page 50: ...overload of the wire drive slave drive Do not place the liner in tight radii check wire core for smooth movement 58 Short circuit Check welding circuit for short circuit Check welding circuit isolate...

Page 51: ...The welding circuit inductance is too high for the selected welding task 10 Partial inverter One of several partial inverters is not supplying welding cur rent 11 Excess temperature coolant 3 Coolant...

Page 52: ...eck that they are fitted correctly Loose welding current connections Tighten power connections on the torch and or on the workpiece Properly fasten the contact tip and contact tip holder Collective in...

Page 53: ...ing Reset triggered fuse rear of the power source by pressing the key button Kinked hose packages Extend and lay out the torch hose package Wire guide core or spiral is dirty or worn Clean core or spi...

Page 54: ...g order Figure 7 3 Switch off machine at the main switch Disconnect mains plug Insert a plain slot screwdriver with a maximum tip width of 6 5 mm through the maintenance opening and place in the centr...

Page 55: ...inch mm inch mm inch l 1152 45 3 854 33 6 854 33 6 b 686 27 0 590 23 2 400 15 7 h 976 38 4 976 38 4 881 34 7 Weight 1 kg lb kg lb kg lb F06G 110 9 244 4 100 7 222 0 85 7 188 9 F06W 125 5 276 6 115 3 2...

Page 56: ...l min 1 3 gal min 20 l min 5 2 gal min max delivery height 35 m 115 ft 45 m 148 ft Max pump pressure 3 5 bar 0 35 MPa 4 5 bar 0 45 MPa Pump Centrifugal pump Max tank capacity 8 l 2 1 gal Flow monitori...

Page 57: ...ass 3 H protection classification Residual current circuit breaker IP 23 Type B recommended Noise level 6 70 dB A Ambient temperature 7 25 C to 40 C Machine cooling Torch cooling Fan AF gas or water M...

Page 58: ...protection classification Residual current circuit breaker IP 23 Type B recommended Noise level 6 70 dB A Ambient temperature 7 25 C to 40 C Machine cooling Torch cooling Fan AF gas or water Mains co...

Page 59: ...H protection classification Residual current circuit breaker IP 23 Type B recommended Noise level 6 70 dB A Ambient temperature 7 25 C to 40 C Machine cooling Torch cooling Fan AF gas or water Mains c...

Page 60: ...s 3 H protection classification Residual current circuit breaker IP 23 Type B recommended Noise level 6 70 dB A Ambient temperature 7 25 C to 40 C Machine cooling Torch cooling Fan AF gas or water Mai...

Page 61: ...L 1 m Extension connecting cable 092 000201 00002 FRV 7POL 5 m Extension connecting cable 092 000201 00003 FRV 7POL 10 m Extension connecting cable 092 000201 00000 FRV 7POL 15M Extension connecting c...

Page 62: ...pert XQ 2 0 with LAN Wi Fi gate way including interface for barcode scanner 092 003496 00000 OU 2DV Conversion kit for two wire feeders 092 003497 00000 OU AIF F06 Conversion kit 19 pole interface for...

Page 63: ...ndix Searching for a dealer 099 005649 EW501 19 11 2020 63 10 Appendix 10 1 Searching for a dealer Sales service partners www ewm group com en specialist dealers More than 400 EWM sales partners world...

Reviews: