Design and function
MIG/MAG welding
62
099-005215-EW501
29.06.2011
5.7.19
Advanced settings
The special parameters cannot be viewed directly since they are normally only set and stored once. The
machine control offers the following special functions:
5.7.19.1
Selecting, changing and saving parameters
0
1
0
1
HOLD
A M P
VOLT
PROG
m /m in
m /m in
Figure 5-34
NOTE
ENTER (Enter the menu)
• Switch off machine at the main switch.
• Press and hold the "left parameter selection" button and switch the machine on again at the
same time.
NAVIGATION (Navigate the menu)
• Select parameters by turning the "welding parameter setting" rotary dial.
• Set or change the parameters by turning the "arc length correction/select welding program"
rotary dial.
EXIT (Exit the menu)
• Press the "right parameter selection" button (switch machine off and on again).