![EWM Saturn 301 KGE M1.02 Operating Instructions Manual Download Page 32](http://html1.mh-extra.com/html/ewm/saturn-301-kge-m1-02/saturn-301-kge-m1-02_operating-instructions-manual_2448197032.webp)
Machine description – quick overview
Machine control – Operating elements
32
099-004968-EW501
27.09.2011
4.3.3.7
Welding parameter ignition time "tZn" diagram
NOTE
In the ignition time, the wire feed continues to run at creep speed after the arc is ignited;
the ignition behaviour is improved with the optimum setting.
The factory setting is that the ignition time is already optimally preset for various materials. The
process described below is always used if there is a pause between welding processes of not
less than 1.5 seconds.
Figure 4-10
Legend with an explanation of symbols can be found in the MIG/MAG function sequences /
operating modes chapter.