Design and function
Transport and installation
099-005325-EW501
01.02.2017
21
• Insert the end of the hose package through the strain relief of the hose package and lock by turning to
the right.
• Insert the plug on the welding current lead into the welding current connection socket "+" and lock.
• Insert cable plug on the control lead into the 7-pole connection socket and secure with crown nut (the
plug can only be inserted into the connection socket in one position).
• Lock connecting nipples of the cooling water tubes into the corresponding quick connect couplings:
Return line red to quick connect coupling, red (coolant return) and
supply line blue to quick connect coupling, blue (coolant supply).
5.1.6
Welding torch cooling system
Insufficient frost protection in the welding torch coolant!
Depending on the ambient conditions, different liquids are used for cooling the welding
torch > see 5.1.6.1 chapter.
Coolants with frost protection (KF 37E or KF 23E) must be checked regularly to ensure that the
frost protection is adequate to prevent damage to the machine or the accessory components.
• The coolant must be checked for adequate frost protection with the TYP 1 frost protection
tester .
• Replace coolant as necessary if frost protection is inadequate!
Coolant mixtures!
Mixtures with other liquids or the use of unsuitable coolants result in material damage and
renders the manufacturer's warranty void!
• Only use the coolant described in this manual (overview of coolants).
• Do not mix different coolants.
• When changing the coolant, the entire volume of liquid must be changed.
Dispose of the coolant in accordance with local regulations and the material safety data sheets
(German waste code number: 70104).
May not be disposed of in household waste.
Prevent entry into sewers.
Absorb with liquid-binding material (sand, gravel, acid-binding agents, universal binding agents,
sawdust).
5.1.6.1 Approved coolants overview
Coolant
Temperature range
KF 23E (Standard)
-10 °C to +40 °C
KF 37E
-20 °C to +10 °C
5.1.6.2 Maximal hose package length
Pump 3.5 bar
Pump 4.5 bar
Machines with or without separate wire feeder
30 m
60 m
Compact machines with additional intermediate
drive (example. miniDrive)
20 m
30 m
Machines with separate wire feeder and additional
intermediate drive (example: miniDrive)
20 m
60 m
Data as a rule refer to the entire hose package length
including welding torch. The pump output is shown on the type plate (parameter: Pmax).
Pump 3.5 bar: Pmax = 0.35 MPa (3.5 bar)
Pump 4.5 bar: Pmax = 0.45 MPa (4.5 bar)