Design and function
MIG/MAG welding
099-005183-EW501
17.12.2010
69
Display Setting/selection
Block JOB mode
0 = Block JOB mode not enabled (Ex works)
1 = Block JOB mode enabled
Program selection with standard torch trigger
0 = no program selection (Ex works)
1 = program selection possible
5.7.21.2
Reset to factory settings
NOTE
All special parameters saved by the user will be overwritten by the factory settings!
Displays
Operating
element
Action Result
Left Right
0
1
Switch off welding machine
VOLT
PROG
Keep the button pressed
0
1
Switch on welding machine
VOLT
PROG
Release the button,
wait about 3 seconds
0
1
0
1
Switch off welding machine and restart in order
to put the changes into effect