Design and function
Configure welding torch
099-500050-EW501
04.08.2016
25
5.2
Configure welding torch
5.2.1
Turning the torch neck
This function is only available with the "CG" and "CW" version!
• Unfasten the crown nut by several turns from the handle until the torch neck can move freely.
• Rotate the torch neck into the required position.
• Tighten the crown nut hand-tight until the torch neck can no longer be moved.
5.2.2 Changing
the
torch
neck
WARNING
Risk of burning or electric shock at the torch neck!
The torch neck and coolant (with water-cooled machines) become very hot during
welding.
You may get into contact with hot components or voltage when turning or changing the
torch neck.
• Switch off the power source and let the torch cool down!
• Wear dry and undamaged protective clothing (shoes with rubber soles/welder's gloves made
from leather without any studs or braces)!
Welding torches can be fitted with a 45°, 36°, 22° and 0° angled torch neck as an option. To replace the
torch neck follow these instructions.
22°
0°
36°