Design and function
Transport and installation
26
099-005207-EW501
18.05.2017
Item Symbol
Description
0
5
Workpiece lead
6
Workpiece
• Insert the central plug for the welding torch into the central connector and screw together with crown
nut.
• Insert cable plug on the workpiece lead into the connection socket for workpiece lead and lock by
turning to the right.
5.1.8
Wire feed
CAUTION
Risk of injury due to moving parts!
The wire feeders are equipped with moving parts, which can trap hands, hair, clothing
or tools and thus injure persons!
• Do not reach into rotating or moving parts or drive components!
• Keep casing covers or protective caps closed during operation!
Risk of injury due to welding wire escaping in an unpredictable manner!
Welding wire can be conveyed at very high speeds and, if conveyed incorrectly, may
escape in an uncontrolled manner and injure persons!
• Before mains connection, set up the complete wire guide system from the wire spool to the
welding torch!
• Check wire guide at regular intervals!
• Keep all casing covers or protective caps closed during operation!
5.1.8.1 Open the protective flap of the wire feeder
To perform the following steps, the protective flap of the wire feeder needs to be opened. Make
sure to close the protective flap again before starting to work.
• Unlock and open protective flap.
5.1.8.2 Inserting the wire spool
CAUTION
Risk of injury due to incorrectly secured wire spool.
If the wire spool is not secured properly, it may come loose from the wire spool support
and fall to the ground, causing damage to the machine and injuries.
• Make sure to correctly fasten the wire spool to the wire spool support.
• Before you start working, always check the wire spool is securely fastened.
Standard D300 wire spool holder can be used. Adapters > see 9 chapter are required when using
standardised basket coils (DIN 8559).