background image

CONV Pelco To Bosch - firmware 0.01.xx 

Ewimar Sp. z o.o. 
www.ewimar.pl 

Made in Poland 

Known problems and their solutions 

 

No control Bosch Speed Dome - the green LED blinks during control, the red LED does not blink 

1.  Set the green LED to display only valid packets. 
2.  If the green LED is not blinking, check the connection and transmission parameters. 
3.  If the green LED is blinking, check if the camera address you want to control is set in the converter. 

 

No control Bosch Speed Dome – the green LED blinks on the control, the red LED blinks from time to time. 

1.  Check the correct connection between the converter and the keyboard. 
2.  Check if the RS-485 terminating resistors are included in the keyboard and converter, if the distance 

between the converter and the keyboard are over 100m 

3.  Check the power supply stability of the converter 
 

No control Bosch Speed Dome – green and red LED blinks. 

1.  Check the correct connection of the cables between the converter and the camera. 
2.  Check if the Bosch output protocol is suitable for the controlled cameras, check for OSRD transmission 

speed 

3.  Check if the termination switch for the Bosch port is included. For Biphase it should be attached. 
4.  Check the camera address settings. 

 

Time to time there is no camera control or the camera rotates continuously and cannot be stopped. 

1.  Set the red LED to display erroneous packets. 
2.  If the red LED blinks frequently, transmission is interrupted as a result of incorrect connections or data 

collision with another control device. 

3.  Check if the termination resistors are included in the converter and in the camera. 
4.  Possible interference from the ground loop effect - a data separator is required. 

 
No LEDs light up when attempting to control.

 

1.  Set the green LED to display all data. 
2.  If the green LED is blinking, verify the baud rate and protocol settings on PTZ keyboard and in the 

converter. 

3.  If the green LED is not blinking, check the connections between the keyboard and the converter. 

4. 

Check the converter power supply. Restart power - after connecting power supply red diode should blinks 
several times.

 

 
 

The device failed to start despite the above tips? Contact Ewimar Sp z o.o. Technical Support.

 

 
 
 
The converter is a specialized product and to connect and run this product, basic electronic knowledge, 
knowledge of communication interfaces and issues related to the installation of CCTV devices are 
necessary. The manufacturer is not liable for losses related to the use of the device, failure to operate or 
damage caused by the lack of proper knowledge of the user. This manual does not convey general 
knowledge, only information applicable to this product. 
 
In the absence of operation or malfunction of the device or any complaint, please contact the 
manufacturer immediately. 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CONV Pelco to Bosch

Page 1: ...d version free for the Lite version 3 Advanced PAN TILT Joystick Curve Correction function individually for each camera optional license for the Standard version free for the Lite version 4 Simultaneo...

Page 2: ...he correct packets have been received does not mean that they will be translated because it also depends on settings the supported addresses by the converter DIP SWITCHES Designed to switch on termina...

Page 3: ...ta The right panel displays the command sent to the converter and its response about a changed setting or an error Each command must be entered in full syntax letters dashes etc and the allowable rang...

Page 4: ...cribed in the extended manual downloaded with the Get user manual button Always active in Lite version active in Standard version after purchasing the license List of translated commands from the Pelc...

Page 5: ...tern A ON 100 ETER 47 Set preset 112 Record pattern A ON 101 ETER 48 Set preset 113 Tour edit 1 ON 900 ETER 49 Set preset 114 Auto Pan Scan 1 ON 14 ENTER plus 50 Set preset 115 Tour Speed 1 ON 15 ENTE...

Page 6: ...T PRESET 128 SET PRESET 1 SET PRESET 100 SEND AUX ON 997 SET PRESET 128 SET PRESET 9 SET PRESET 97 Example of remote FastAddress address change for camera G4 series Step Command Sequence from the Pelc...

Page 7: ...continuously and cannot be stopped 1 Set the red LED to display erroneous packets 2 If the red LED blinks frequently transmission is interrupted as a result of incorrect connections or data collision...

Page 8: ...ed for work within the EU and is compliant with essential requirements and other relevant provisions of EMC Directives 2014 30 EU and 2011 65 EU RoHS directive PN EN 61000 6 3 2008 A1 2012 Electromagn...

Reviews: