17
6.0 In s ta llation
6.0 Installation
Authorized personnel
The installation and initial operation may only be conducted
by qualified personnel.
WARNING
Risk of injury and material damage due to incorrect installation
of the device.
Therefore:
• Devices may only be installed in accordance with their re-
spective instructions.
6.1 Installation location
To determine the proper location for the module, adhere to
the technical data (see Appendix).
Install in a location where the module is not exposed to
strong UV radiation or corrosive or explosive air media.
6.2 Inspections prior to
initial operation
Performed by professional electrician.
Prior to the initial operation, a professional electrician must
perform and document the following tests and readings:
• Check visual condition.
• Function check of operation features and safety features.
Note
See additional information concerning inspection and readings
(see 8 Maintenance).
6.3 Installation
DANGER
Hazard of installation by unauthorized personnel
To prevent injury and damage to the property, installation has to
be performed by trained personnel..
The CLSM linear module is attached to the application by
fixing bolts on the bottom plate of the module.
Note
To check the dimensions of the drill hole of the linear module
for fastening bolts, see the drawings in the data sheets (see
Appendix 1).
DANGER
Risk of incorrect installation
• Do not support the CLSM linear module by only part of the body.
It should be installed to support the weight of the entire body and
loads.
• Make sure the fixing surface of the application is evenly flat.
1. Assemble the motor onto the linear module if the product
is not pre-mounted.
2. Secure elements of the application in which the linear
module will be installed.
3. Secure the bottom plate using pins.
130
+0,02
-0.02
Pin specification
Value
Unit
Pin size
Ø 6 H7 pin Hole DP 10