2015
Goodman
Manufacturing
Company,
L.P.
Installation
When
the
outdoor
unit
has
a
transformer
and
there
are
3
wires
available,
use
the
3
rd
(spare)
wire
to
connect
the
two
24v
commons
together.
That
will
ensure
both
24v
commons
are
at
the
same
ground
potential
Thermostat
Wire
Between
All
Units
WHITE
YELLOW
GREEN
RED
1
C
2
R
1
2
R
1
2
R
C
C
230V
24VAC
Outdoor
Board
Terminal
Connections
Field
Installed
or
Dedicated
Outdoor
Transformer
Indoor
Board
Terminal
Connections
UT3000
CTK04
CTK03
CTK02
CTK01
Use
the
spare
wire
24VAC
(Hot)
24VAC
(Common)
Data
1
Data
2