PROGRAMMING
CONFIGURATION

Permanent Override or a Designated Day Override

To hold your Manual Override for a designated number of days.

1) 

Press the         

 

key once to make the current program temperature the 

HOLD temperature. “Permanent Override” will be displayed on the LCD 

and the program number will disappear.

2)

 Use the          

  

or            keys to set the Permanent Manual Override 

temperature you desire.

3)

 Press         

 

 key to initiate Permanent Manual Override or wait 20 

seconds for it to take effect.

You are now set in Permanent Override Mode. To set your thermostat to 

hold it for a designated number of days:

1)

 Press the          key once. Override Until 

1 Days

 will appear on the LCD 

and the clock will disappear.

2)

 Press the          key to adjust the number of override days.

3) 

After 30 seconds the change will take affect.

HOLD

/RUN

HOLD

/RUN

HOLD

/RUN

DAY/
TIME

HOLD

/RUN

To end Override:

To end a Designated Day Override, press the

          

 key once. The 

thermostat will return to the current program and the HOLD will be 

canceled.

To end Permanent Override press the          key twice. 

Auto Changeover

When the system mode selector is in the AUTO position, the 

thermostat will automatically change between Heating and Cooling 

modes as the actual room temperature fluctuates.  We recommend 

keeping the programmed heating and cooling temperature at least 3° 

apart to allow the Auto Changeover to occur when the appropriate 

temperature span has been reached.  For example, you may have the 

following  temperatures programmed at a given time:

Heat Set Temp = 68°F, Cool Set Temp = 78°F

If the room temperature rises above 78°F, then the thermostat will 

automatically change to cool mode and turn on the air conditioner.  

Likewise, the thermostat will automatically switch to heat mode and 

turn on the heat when room temperature falls below 68°F. In between 

68°F and 78°F - no system operation will occur.

Auto Recovery

Auto Recovery calculates when to start the HVAC system in order to 

reach the programmed set-point at the programmed time.  Auto 

Recovery can be enabled or disabled in step 4 of the installer 

configuration menu.

Auto Recovery will not operate if Permanent Hold or Temporary Hold is 

in operation. 

The Heat set point can not be set higher than the Cool set point, and the 

Cool set point can not be set lower than the Heat set point.

                             

1) 

Put Thermostat into 

RUN MODE 

in either heat or cool.

2) 

Select program mode, either 5-2 day or 7 individual days by 

pressing           key until desired program is selected.

3) 

Press          key and in the program window will appear the 

hour flashing. Use the             

 

or            

 

keys to set the 

hour. Note AM or PM.

4) 

Press        

  

key

 

again to change to the minute position.

Use         

   

or             keys  to change the minute.

5)

 Press          key again to set to the program COOL set 

temperature. Use the  

           

or             

 

keys to set to your 

desired temperature setting.  

6) 

Press         key again to set to the program HEAT set 

temperature. Use the             or 

             

keys to set to your 

desired temperature setting.  

  Program 1 is Complete

7) 

Press         

 

key to move to program 2, 3 and 4 and follow 

the same steps.

PROG

PROG

DAY

PROG

PROG

PROG

PROG

Programming Temperature Settings

The EWT-3900 Thermostat can be programmed for 
weekdays and weekends [5/2] or have a unique program for 
each of the 7 days of the week. Each day can have a 
maximum of 4 time and temperature settings for heating and 
cooling.  With the “Auto Recovery” feature enabled, the 
thermostat will advance the program based on temperature 

difference [

D

t] of the current temperature and the next 

desired set point.
The program time can be set in 10-minute increments, and 
remains the same for both heat and cool programs.
The program temperature can be set in increments of 1°F 
(1°C).
The Heat set point can not be set higher than the Cool set 
point, and the Cool set  point can not be set lower than the 
Heat set point.

HOLD

/RUN

thermostat #

FCC ID:XLXA3900

QC

Pass

1. After initial battery conditioning, charge the battery every 3 months for best operation.
2. If communication is lost follow the syncing instructions.
   a. Make sure the Thermostat is in the OFF position.
   b. Press and hold the PROG key for 3 seconds until the screen changes to the
       Menu screen.

   c. Press the PROG key to scroll through the menu until the LCD displays CRES.

   d. Use the UP key to select 1. Press the Matching Key on the Receiver and then

       press the center button between the UP and DOWN arrows on the Thermostat.

   e. Wait for 30 seconds, the Thermostat will force the receiver to link.

    f. Test by selecting Fan ON in the thermostat screen. Wait for the radio signal icon 

       to flash on the screen.  The HVAC fan should energize. You may now operate your 

system normally.

receiver #

receiver #

thermostat #

FCC ID:XLXA3900

If you have more than one EWT-3900 installed on your system, 
be sure to number each receiver with its corresponding 
thermostat after removing them from the box.

1

1

Summary of Contents for EWT-3900 Ultra-Zone

Page 1: ...Thermostat can be programmed between 45 F and 95 F l Backlit display l Air Filter Replacement Monitor The Model EWT 3900 Wireless Thermostat is Linked to the Receiver at the factory Simply power up the Receiver then program and operate the Thermostat AUTO FAN SYSTEM HEAT PM 1 MON Room DAY TIME PROG PROG DAY FAN HOLD RUN MODE Reviews filter usage in hours and minutes and also activates standby mode...

Page 2: ...han is subject to freezing and or condensation EWC Controls Inc 385 Highway 33 Englishtown NJ 07726 800 446 3110 FAX 732 446 5362 E Mail info ewccontrols com 2 CAUTION To prevent electrical shock and or equipment damage disconnect electric power to HVAC system at main fuse or circuit breaker box until installation is complete WARNING Do not use circuits exceeding specified voltage Higher voltage w...

Page 3: ...lower Fan Energized on call for Heat and Cool Energized in Cool Mode Energized in Heat Mode Heat Pump 2 2nd Stage Compressor THERMOSTAT TERMINALS CONVENTIONAL SYSTEM C R E W1 W2 Y1 Y2 G O B Single Stage 24 Volt Common 24 Volt hot Heat Mode 1st stage No Output Cool mode 1st stage compressor No output Blower Fan Energized on call for Cool and Heat if HE was selected No Output No Output Multistage 2n...

Page 4: ... hold the key for five seconds to enter the configuration menu The display will show the first item in the configuration menu The configuration menu table shows the configuration options and an explanation of each option Press the key to step to the next menu item To exit the menu and return to program operation press key If no keys are pressed within fifteen seconds the thermostat will revert bac...

Page 5: ...et point and the Cool set point can not be set lower than the Heat set point 1 Put Thermostat into RUN MODE in either heat or cool 2 Select program mode either 5 2 day or 7 individual days by pressing key until desired program is selected 3 Press key and in the program window will appear the hour flashing Use the or keys to set the hour Note AM or PM 4 Press key again to change to the minute posit...

Page 6: ...he heating system should stop operating Copyright 2009 EWC Controls All Rights Reserved FAN FAN MODE Heating System Heatpump Application Only 1 Press the key until HEAT shows on the LCD display 2 Press key to adjust thermostat setting to 2 F 1 C above room temperature The heating system should begin to operate The display should show STG1 However if the set point temperature display begins to flas...

Page 7: ...revent unauthorized changes from being made To lock or unlock the keyboard press and hold the button for 3 seconds The keyboard is locked when LOCK appears on the display Anytime a key is pressed LOCK will appear on the screen for one second To exit Lock mode press and hold the key for 3 seconds Filter Monitor Your thermostat also keeps a record of the number of days your filter has been in use To...

Page 8: ...L EWT BC USB CABLE INCLUDED WITH EWT 3900 MODEL EWT 3900 The Model EWT BC is an optional wall charger for the Model EWT 3900 Wireless Thermostat TO USE Attach the USB Cable Provided with the EWT 3900 to the Thermostat and the Charger Then plug the charger into the wall Allow the thermostat to charge for at least 12 hours during the first three charging cycles in order to condition the battery prop...

Page 9: ...adio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or instal...

Page 10: ...This page is left blank intentionally EWC Controls Inc 385 Highway 33 Englishtown NJ 07726 800 446 3110 FAX 732 446 5362 E Mail info ewccontrols com Copyright 2009 EWC Controls All Rights Reserved ...

Reviews: