background image

 

 

 

x

 

Other storage information is retained for a maximum of 10 years in the event of a power 
failure. 

x

 

Operating  temperature  range:  -20°C  to  +70°C  at  20–80%  relative  humidity,  non-
condensing.  

x

 

Storage temperature range: -40°C to +90°C.  
 

 

Interfaces 

 
Power supply input via a connection cable coming from the power supply unit (either directly or 
via the optional I/O box). 

x

 

inputs switchable to earth for optional connection of bolt contact, door contact and door 
push-button. 

x

 

RS485  wired  interface  protocol  for  connecting  an  optional  I/O  box  via  two  connecting 
cables.  Two  of  the  inputs  described  above  are  used  for  RS485.  These  are  determined 
during implementation. 

x

 

BLE  interface  for  configuration  via  mobile  device,  as  preparation  for  future  wireless 
connection of an optional I/O box.  

x

 

Thumbturn button with mechanical detection of manual actuation. 

x

 

Output of the visual door status display. 

x

 

The motorised thumbturn electronics are fixed inside the motorised thumbturn body 

 
 

1.1.3

 

Motor thumbturn firmware 

 

The  motorised  thumbturn  firmware  includes  all  firmware-based  components  that  enable 
electrical  locking  and  release  as  well  as  additional  functionality  such  as  configuration,  self-
learning or mode switching. 

 

Firmware functions 
 

x

 

Configuration, status queries and FW updates are carried out via a BLE interface. 

x

 

Optional I/O boxes are also configured and updated by the motorised thumbturn. Transfer 
of configuration files and firmware images via the RS485 bus. 

x

 

After starting the commissioning via BLE interface, the motor thumbturn firmware adjusts 
autonomously to the installation situation. 

x

 

Operating mode changeover can be triggered by pressing the thumbturn button (> 5 s); 
the most recent changeover always applies, regardless of the source. 

x

 

Possibility  of  deactivating  the  thumbturn  button  to  prevent  manual  opening  from  the 
inside if required. 

x

 

Automatic detection of whether a wired RS485 connection is active or whether door push-
button and/or door contact or bolt contact are directly connected to the motor thumbturn 
via an input connected to earth. 

 
 
 
 

 

Instructions for use and maintenance can be found in the operating manual. 
You can find these either in the product packaging or in the download area of 
the EMZY website: 

 

https://www.evva.com/emzy/

 

 

 

Summary of Contents for EMZY

Page 1: ...System manual EMZY ...

Page 2: ...at de service downloads All rights reserved This system manual must not be reproduced copied or adapted neither in full or in part using electronic mechanical or chemical methods or any other procedures without the written consent of the publisher We shall not assume any liability for technical or printing errors and their potential consequences However the data in this system manual is revised re...

Page 3: ... 6 2 1 Motorised thumbturn 6 1 1 1 Motorised thumbturn mechanism 6 1 1 2 Motorised thumbturn electronics 7 1 1 3 Motor thumbturn firmware 8 2 2 I O box 10 2 2 1 I O box mechanics 10 2 2 2 I O box electronics and firmware 10 2 3 Accesories 11 2 4 Connection diagrams 11 3 EMZY app 12 3 1 App structure 12 3 2 Search 12 3 3 Settings 12 3 4 Info 15 ...

Page 4: ...g Conditions You can access the EVVA General Terms and Conditions and EVVA General Terms and Conditions at https www evva com at de impressum The above information must be observed and relates to the manufacturer s liability for its products as defined in the Product Liability Act and must be forwarded to the operators and users Non compliance releases EVVA from any liability Unauthorised use repa...

Page 5: ...histicated and proven product for automatic locking and release If you require additional support please contact your EVVA partner directly You can access the list of certified EVVA Partners here https www evva com at de haendlersuche General information on EMZY can be found here https www evva com emzy 1 3 Explanation of Symbols For greater clarity the following symbols are used in the system man...

Page 6: ...5 Links Step by step instructions ...

Page 7: ...ning from the inside at any time by manually turning the motor thumbturn even during a power failure x It is possible to mechanically remove the twist grip i e the body to facilitate dismantling and servicing of the motorised thumbturn Mechanical compatibility with the following EVVA thumbturn cylinder products x MCS x 3KS x 3KS x 4KS x ICS x EPS x Akura44 in preparation An EMZY cylinder as ordere...

Page 8: ...FKHRQ x Operating temperature range 20 C to 70 C at 20 80 relative humidity non condensing x Storage temperature range 40 C to 90 C x IP class IP54 x 7RUTXH 1P DW WKH FDP DGDSWLYH DGMXVWDEOH x Opening speed 1 5 s lock cycle x 2SHQLQJ F FOHV RQH F FOH FRQVLVWV RI URWDWLRQV opening and closing 1 1 2 Motorised thumbturn electronics The motorised thumbturn contains all the electronic components that m...

Page 9: ...irmware includes all firmware based components that enable electrical locking and release as well as additional functionality such as configuration self learning or mode switching Firmware functions x Configuration status queries and FW updates are carried out via a BLE interface x Optional I O boxes are also configured and updated by the motorised thumbturn Transfer of configuration files and fir...

Page 10: ...9 ...

Page 11: ...ion of various control elements such as door push button door contacts bolt contacts and external control and signalling interfaces In addition it supplies the motor thumbturn with power via a power supply unit connected by means of a connecting cable Functions x Actuation of the EMZY by access systems with identification capabilities via input connected to ground e g o Xesar wall reader connectio...

Page 12: ...er supply unit x The I O box electronics are fixed inside the I O box housing Features which are not related to functionality x Can be fitted in a standard surface mounted box 10 10 cm w o communication module x Fitted with pluggable and reverse polarity proof screw terminals Phoenix screwless terminals as in the AirKey control unit x DEOHV PPð FURVV section can be connected x Preparation define i...

Page 13: ... can also be updated under New search Clicking on EMZY opens the password entry screen The password and QR code are on the provided EMZY password card 3 3 Settings Settings includes commissioning manual settings status display security settings and firmware update Commissioning The EMZY and its components are ready for operation as soon as commissioning is completed The process is guided step by s...

Page 14: ... retraction can be set in office mode Motor thumbturn inputs As during commissioning inputs can be configured retrospectively here The integrated thumbturn button can be deactivated or operated as an intelligent thumbturn button The intelligent thumbturn button acts as an operating mode switch and switches after the preset time to the other mode I O box inputs Various I O box inputs can be set and...

Page 15: ...s Various time settings can be made here Status The commissioning values EMZY values statistics and alarm statuses are displayed under Status Security The EMZY name and password can be changed under Security The EMZY factory settings can also be reset here Software Update The EMZY thumbturn and I O box firmware are updated using the software update function ...

Page 16: ...lso offers an additional download option for sending data to EVVA Support Data protection provisions Direct access to the data protection provisions Licences A list of all licence agreements and licences used GENERAL TERMS AND CONDITIONS OF BUSINESS Direct access to legal information and general terms and conditions Program libraries Displays the list of all program libraries used App version This...

Reviews: