12
manufacturer. The connections can also be determined using a
multimeter.
USE WITH ANOTHER MOTOR LOCK
For use with a motor lock (that has 0 resistance between signal
cables when locked, and infinite resistance when unlocked) the
charge controller lock outputs are configured as follows:
B – signal. If the motor is 12V is expected, if it is in
unlocked state, 0V is expected.
R and W – Locking of motor is powered through these outputs for
locking and unlocking. Locking is done with 600ms pulse. If it is
detected that the motor has not functioned, the locking/unlocking
action is repeated after 5 seconds. If the locking action is reverse,
the wires should be swapped between R and W connections.
Connection of another motor:
L
N
CONT
Y
G
R
PE
B
R
W
PE
CP
PP
IC
PE
M
W
R
B
Blue/Yellow
Blue/Green
Blue/Brown
Blue/Red
R=
R=0