EVSE 3727 Series User Manual And Installation Manual Download Page 1

 

Control Module Inc., EVSE LLC

 

EVSE Gateway Module 

Model 3727 Family 

 

 

 

 

 

 

User Manual and Installation Guide 

Model 3727 Family 

EVSE Gateway Module  

Patents Pending  

3727-UG-200  

November 2017 

Summary of Contents for 3727 Series

Page 1: ...Control Module Inc EVSE LLC EVSE Gateway Module Model 3727 Family User Manual and Installation Guide Model 3727 Family EVSE Gateway Module Patents Pending 3727 UG 200 November 2017 ...

Page 2: ... 7 Specifications 8 Lockout Tagout 10 Installation 11 Wiring 12 Indicator Lights Cell Modem Status 13 Indicator Lights Server LEDs 14 Accessing the Web Browser Interface 15 Ethernet Connection 15 Cellular Connection 15 Logging In 15 Changing the IP Address for an Ethernet Connection 16 Setting Up a ZigBee Mesh Network 17 Testing the ZigBee Mesh Network 18 Replacing a ZigBee Mesh Gateway Module 19 ...

Page 3: ...State of the Art EVSE User Manual Model 3727 A02XX EVSE Gateway Copyright EVSE LLC 2017 All rights reserved Patents pending Page 2 Moving Transporting and Storage 26 Customer Support 27 Warranty 28 ...

Page 4: ... implied warranties including any warranty of design merchantability fitness for particular purposes and non infringement to the maximum extent permitted by law Limitation of Liability IN NO EVENT SHALL CONTROL MODULE INC EVSE LLC OR ITS AUTHORIZED DISTRIBUTORS BE LIABLE FOR ANY INDIRECT INCIDENTAL SPECIAL PUNITIVE OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS LOST DATA LOSS O...

Page 5: ...er countries It may not be modified reproduced or distributed without the prior express written consent of Control Module Inc EVSE LLC Watt Point is a U S registered trademark and service mark of Control Module Inc EVSE LLC All other products or services mentioned have the trademarks service marks registered trademarks or registered service marks of their respective owners Control Module Inc EVSE ...

Page 6: ...tional Electrical Code ANSI NFPA 70 for proper sizing of the ground conductor CAUTION To reduce the risk of fire when installing the Gateway connect only to a dedicated circuit with 15A maximum branch circuit over current protection in accordance with the National Electrical Code ANSI NFPA 70 To satisfy FCC RF exposure requirements for mobile transmitting devices a separation distance of 20 cm or ...

Page 7: ...uit dédié avec protection maximum des branches des over current circuits 15A bis conformément aux dispositions du Code électrique National ANSI NFPA 70 Pour satisfaire les exigences d exposition RF de la FCC pour les appareils mobiles de transmission une distance de séparation de 20 cm ou plus devrait être maintenue entre l utilisation de ce dispositif et les personnes au cours de l opération de l...

Page 8: ...eway Module is able to communicate to third party systems via Ethernet which is standard with the unit An optional cellular modem is also available The modem is configured to be compatible with either of the AT T or Verizon networks but not both simultaneously The Gateway Module is packaged in a NEMA 3R rated enclosure so it is compatible with outdoor conditions while providing a degree of protect...

Page 9: ...vironmental 1 GHz IEEE 802 3 10Base T and 802 3u 100Base T Frequencey 2 4 GHz Operating Temp Operating Humidity NEMA Rating Compliance 22F to 122F 30C to 50C Ambient 0 to 90 non condensing 3R EMC Accessories Meets FCC Class A Canadian ICES 003 Communication to EVSE ZigBee Communication to Network Cellular Modem Contains FCC ID MCQ PROS2B IC 1846A PROS2B optional Contains V FCC ID N7N SL5011 IC 241...

Page 10: ...Pole with 1 4 Mux includes standalone Gateway 3x6 pole 1 4 EVSE serial P3 Pole with 5 8 Mux includes standalone Gateway 3x6 pole 5 8 EVSE serial P4 Pole Gateway Tower P5 Pole with Pole w POE for ZigBee communication P6 Wall Includes standard wall frame and 24 VDC power supply for ZigBee com W1 Wall with 1 2 Mux includes Gateway wall frame mux 1 2 EVSE serial W2 Wall with 1 4 Mux includes Gateway s...

Page 11: ...solation device circuit breaker to ensure that the power source cannot be operated until the lockout device is removed A lockout device utilizes a positive means such as a lock key or combination lock with a circuit breaker lockout to hold the breaker in a safe position to prevent energization Tagout is the placement of a tagout device a tag or other prominent warning device on an energy isolation...

Page 12: ...A02XX EVSE Gateway Copyright EVSE LLC 2017 All rights reserved Patents pending Page 11 Installation The Gateway Module is easily mounted to the wall or a pole See the 3725 series of Installation Sheets for more information Back of Gateway Figure 1 ...

Page 13: ...Copyright EVSE LLC 2017 All rights reserved Patents pending Page 12 Wiring An internal view of the 3727 Gateway Module wiring Figure 2 is a cellular ZigBee version Figure 2A is serial Zigbee and Figure 2B is serial only Figure 2 Figure 2A Figure 2B Ethernet Ethernet ...

Page 14: ...It is finally solid when the device is authenticated on the cellular network and is provided an IP address by the cellular network Signal A slow blink indicates a signal is being received RSS Signal LED Status Ranges of RSSI dBm Slow Blink 90 to 99 Not Lit Equal to or weaker than 100 Active Lights will flash as data is transferred to and from the cellular modem on the remote network Power This LED...

Page 15: ...ghts Server LEDs These lights reflect communication between the Gateway and the OCPP Server and the Gateway and EVSE The lights blink slow during communication to indicate RXD Signals received on for approximately one minute when a message is received TXD Signals transmitted always on PWR indicates the Gateway is on and receiving power Figure 4 ...

Page 16: ...ble from your laptop into the Ethernet port 2 Bring up a browser on your laptop and enter the Module s default IP address into the URL 3 Log into the Module Username admin Password pass 4 Follow Steps 1 5 in Changing the IP Address for an Ethernet Connection on page 16 5 Remove the Ethernet cable connecting your laptop to the Module and plug in your network s Ethernet cable 6 Slide the Module back...

Page 17: ...Open Sys Config from the dropdown list 2 Click the Network Settings tab The following screen displays 3 Enter a public static IP address for the Module in the IP Address field 4 Fill in the remaining fields as necessary for your system s configuration 5 Click Save Changes The system automatically resets the gateway This will take a few minutes 6 From your network s browser enter http IP address 80...

Page 18: ... switches See that EVSE s installation guide for those instructions Refer to Figure 5 for the EVSE s Data Router dip switch location Note Power must remain on for the Gateway Module and the EVSEs to ensure communication does not get interrupted before the process completes 1 Turn on the Gateway Module 2 Turn on the first EVSE This is usually the EVSE closest to the Gateway Module 3 Slide that EVSE...

Page 19: ... s have been added 11 Once all EVSEs have been added leave the Synch EVSE screen to take the Gateway Module out of Listening Mode Note Adding an EVSE to an existing operational network interrupts communication within the network while the Gateway Module is in Listening Mode Tracking Data that occurred during the time the Gateway Module was in Listening Mode will be collected after the Gateway Modu...

Page 20: ...ion guide for cover removal instructions and remove its cover 3 Slide that EVSE s Data Router Dip Switch number 3 to Closed to put it into ZigBee Setup Mode Figure 5 After a few moments all the lights on the Data Router will begin flashing letting you know the EVSE is now in ZigBee Setup Mode Figure 6 4 From the main Web browser screen select the ZigBee Setup dropdown menu and click Synch Payment ...

Page 21: ...hanging EVSE Assigned Numbers Serial Connection 1 From the main screen expand your list of EVSEs from the EVSE Station dropdown list and click the EVSE number you want to change The following screen displays 2 Enter your preferred number and click Save Changes at the bottom of the screen 3 You must now reset the Module Click File and select Open Sys Config from the dropdown list 4 The following sc...

Page 22: ...ed in you will be brought to the EVSE status screen which provides a list of all EVSEs in the system as well as their current status 1 Select File in the top left corner of the screen to get a dropdown list 2 From the dropdown select Open Comm View This screen will automatically update to display any messages sent to or received from the EVSEs Click arrows to expand option choices Dropdown List ...

Page 23: ...and and view available reports Current Status Current Status view provides a color coded list of all EVSEs and their current state Historical Events The historical events view allows users to display a list of the events that were received by the Gateway Module from each EVSE or a specified EVSE for the specified date range Once a list of events is retrieved specific events can be located by using...

Page 24: ...NMS as part of your setup you need to set up communication between the Gateway Module and the NMS 1 From the Main screen click the arrow next to the Client App folder to expand it and click OcppApp The following screen displays 2 Click the Enable Client Application checkbox 3 Click Save 4 Click OcppWebServices The following screen displays 5 Click the Enable Client Application checkbox 6 Click Sav...

Page 25: ...LC 2017 All rights reserved Patents pending Page 24 8 The following screen displays 9 Click Reset Gateway The Gateway Module resumes operation in approximately 30 seconds Note You will not be able to log back into the Gateway Module s Web Browser page for approximately five minutes ...

Page 26: ...nication is working properly Days to keep local messages retention period for status events Days to keep charge history retention period for charge history MQ URL tcp localhost 61616 specifies the connection information for the Payment Module messaging interface Note This value should not be modified unless directed to do so by Customer Support personnel MQ Test Tests Message Queue operations Post...

Page 27: ...ource before working with electrical wiring AVERTISSEMENT Assurer l alimentation électrique a été fermeture à la source avant de travailler avec câblage électrique Should the Model 3727 200 Gateway Module need to be relocated remove the unit in the reverse order that it was installed Bag all attaching hardware and secure on in the unit Store the unit in a dry low humidity area Protect the unit usi...

Page 28: ...ions about installation operation optional features maintenance or service arise please call Technical Support at 1 888 753 8222 between the hours of 8 30 am to 5 00 pm EST Monday to Friday Letter Service Department Attn Jack Batalha Director Product Support Control Module Inc 89 Phoenix Avenue Enfield CT 06082 Fax 1 860 741 6064 e mail jbatalha controlmod com ...

Page 29: ...l and costs thereof 5 services which cannot be practicably performed due to alterations in or attachments to the equipment or 6 services for accessories This Limited Warranty does not extend to any product for repair or replacement of defective Hardware Equipment that has been damaged or rendered defective a as a result of accident misuse abuse contamination improper or inadequate maintenance or c...

Page 30: ... 3727 A02XX EVSE Gateway Copyright EVSE LLC 2017 All rights reserved Patents pending Page 29 EVSE LLC A Division of Control Module Inc 89 Phoenix Ave Enfield CT 06082 Local Phone 860 745 2433 Toll Free Phone 800 722 6654 evse controlmod com ...

Reviews: