TECHNICAL REFERENCE MANUAL
Dyvi 2.0.7.2
Hardware Specifications
19
5.2
Power Supply
5.2.1 Processing Module
Redundant Power Supply
The server is fitted with two auto switching and hot-swappable power
supplies. The secondary hot-swappable power supply should be
connected to the mains to share the load and to allow automatic power
switching to one power supply in case one of the two should fail.
Warning: Grounding and Power Cabling
•
Ensure the server unit is properly grounded at all times to
avoid electrical shock hazard.
•
Grounding always has to be provided through the protective
earth pin of the power cable. For safe and reliable operation
use only the power cables that come with the server system
package.
Electrical Specifications
Rated voltage
100-127V
Rated frequency
50-60 Hz
Power supply
max. 1000W @100-127V
max. 1600W @200-240V
Input connector
CEE 22/IEC 320 3-pin male receptacle
Electrical Consumption
The following electrical specifications are valid for the Processing Module:
Data Type
Voltage
Value
Maximal current (full load)
110V-220V
~1000W
Typical Consumption
110V-220V
~450-500W