Installing the Gauge Panel
Figure 3: Gauge Panel
1.
Remove two (2) adjacent bolts from the top cover in your desired location to make the pressure gauges easily visible.
2.
Install the 6 inch bolts (provided) in the empty bolt holes and torque to 55 ft-lbs (75 N-m).
3.
Install the gauge panel mounting bracket by inserting the longer flange bolts through the channel in the bracket and
secure with 0.75 inch nuts (included)
4.
Bolt the gauge panel to the mounting bracket using four 0.25 x 1 inch screws, washers, and nuts (included).
5.
Connect 0.25 inch tubing (included) to the gauges using the compression connectors (included)
6.
Connect the tubing to the influent and effluent piping as close to the filter as possible.
0.25 x 1
inch screws
0.25 inch OD
tubing (included)
0.25 inch male compression
connector (included)