background image

9

EVONIC - 104 INSTRUCTION MANUAL TEMPLATE ISS. 1

EVONIC - 104 INSTRUCTION MANUAL TEMPLATE ISS. 1

COSINA ISS. 1

COSINA ISS. 1

 HEARTH SECTION - FIRE CUT-OUT

Check the width of the model you are installing below by scanning 

the QR code, and use a depth of 305mm. Your cut-out depth will now 

line up with the top section of the unit, giving you approximately a 

30mm overhang from the unit. 

Using an appropriate saw, carefully cut these dimensions out of the 

top hearth ready for the fire to be slotted into place. 

On Electra 1250 and 1500 models, which have a narrower case, 

a baton is required to provide extra support to the fire. The baton 

needs to be fixed to the back of the unit. 

305MM

We recommend measuring the width of the case, taking into account the 

fixings on the metalwork which could result in a slight increase in size.

MODEL

CUT-OUT SIZES

E1030 / KIRUNA 

1010mm X 305mm

E1250 / MOTALA / EXOR

1265mm X 305mm

E1500 / LINNEA / LITA

1510mm X 305mm

E1800 / AVESTA / ASTA

1765mm X 305mm

ELECTRA 1250

1265mm X 305mm

ELECTRA 1500

1510mm X 305mm

ELECTRA 1800

1765mm X 305mm

ALISIO 850

864mm X 305mm

ALISIO 1150

1164mm X 305mm

ALISIO 1550

1564mm X 305mm

ALISIO 1850

1864mm X 305mm

Summary of Contents for COSINA

Page 1: ...COSINA COSINA ASSEMBLY MANUAL ASSEMBLY MANUAL COSINA 3 COSINA 4 COSINA 5 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 COSINA ISS 1 COSINA ISS 1...

Page 2: ...crewdriver Drill Phillips drill bit Jigsaw 40 X 4x30 Screws Component list 3 Constructing the end cupboards 4 Constructing the middle cupboards 5 Attaching the cupboard doors 6 Securing the cupboards...

Page 3: ...1 X Hearth top and sides 6 X Hinges 6 X Hinge attachments 40 X 4x30 screws in LH cupboard 1 X Right Hand Cupboard 1 X Left Hand Cupboard 4 X Doors 2 X Central cupboard 1 X Plinth 1 X Hearth top and si...

Page 4: ...THE END CUPBOARDS 1 2 Lay section A face down then insert E and D by slotting the joining tongue into the joining groove at a 45 degree angle then pushing up to a 90 degree angle to secure in place S...

Page 5: ...down then insert E and C by slotting the joining tongue into the joining groove at a 45 degree angle then pushing up to a 90 degree angle to secure in place CONSTRUCTING THE MIDDLE CUPBOARDS Slide se...

Page 6: ...ether you want them situated on the left or right there are holes on either side Attach the door to the cupboards by clicking the hinge in place 6 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 1...

Page 7: ...1 SECURING THE CUPBOARDS IN PLACE 1 Carefully tilt the unit back onto its base You can now begin to secure the cupboards to one another We recommend this step is done by two people to ensure the unit...

Page 8: ...TEMPLATE ISS 1 COSINA ISS 1 COSINA ISS 1 PLINTH INSTALLATION 1 Carefully turn the unit over you can then screw the plinth in place using the screws provided Set the plinth back 25mm from the front of...

Page 9: ...e slotted into place On Electra 1250 and 1500 models which have a narrower case a baton is required to provide extra support to the fire The baton needs to be fixed to the back of the unit 305MM We re...

Page 10: ...accurately in place Using the counter sunk holes screw into place When screwing the hearth into place ensure you do not push too firmly as this could result in the screws breaching the hearth Once fit...

Page 11: ...THE DECORATIVE SIDE PANELS 1 2 3 4 Take the side panel and offer it up to the end cupboard Line the side panel up to the hearth This will ensure you get an even overhang on both sections Using the sc...

Page 12: ...baton to the rear of the unit ensuring that it is central and resting on top of the plinth Once fitted the back of the fire will rest on the baton and the front and sides will be supported by the hear...

Page 13: ...Use a screwdriver for this step and only use a slight turn when adjusting The gap between each cupboard should be the same and the bottom edge of the cupboard doors should all be level 13 EVONIC 104 I...

Page 14: ...MODEL HEIGHT WIDTH DEPTH COSINA 3 420mm 1540mm 420mm COSINA 4 420mm 2040mm 420mm COSINA 5 420mm 2540mm 420mm 14 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS...

Page 15: ...n CV37 8HW Tel 44 0 1789 263868 Fax 44 0 1789 293080 Email sales evonicfires co uk www evonicfires co uk Follow us on Instagram Facebook Twitter LinkedIn evonicfires 15 EVONIC 104 INSTRUCTION MANUAL T...

Reviews: