![Evolve T-100-R Operation Manual Download Page 6](http://html.mh-extra.com/html/evolve/t-100-r/t-100-r_operation-manual_2447301006.webp)
Page 6
Setting Fan Mode and System Status Indicators
Operational Fan Mode
Fan Cycler. If the Fan Cycler feature is enabled in the Installer Setup, the additional fan mode
“Cycle” will be shown in the Fan Mode menu. This mode cycles the fan on and off continuously for
fresh air ventilation according to the settings in the Installer Setup.
System Operation Mode Indicator
“SYS OFF” displayed
System is OFF.
“SYS MOT” displayed
System is OFF and Minimum Off Time (MOT) delay On is active.
“HEAT ON” displayed
System is ON and heating.
“COOL ON” displayed
System is ON and cooling.
“HEART MRT” displayed
System is ON and heating. Min. Run Time (MRT) delay off is active.
“COOL MRT” displayed
System is ON and cooling. Min. Run Time (MRT) delay off is active.
Operation Guide
75
MENU
HEAT
MODE
HOLD
64H
82C
AUTO
FAN
Sys Off
2
nd
Stg
Filter
4:30 PM
System
Status
Indicators
Press the Fan button to change the Fan mode.
•
AUTO FAN: Fan automatically operated by the HVAC
system.
•
FAN ON: Manual Fan mode. Fan stays on until mode
is changed back to Auto.
Staging Display
"2nd Stg" displayed
Stage 2 heating or cooling is ON
"Aux Heat" displayed
Stage 3 heating is ON
Home/Away Display
Home mode is active (current setpoints are being used)
Away setback mode is active (setback points are being used)
System Alerts
Alert Text displayed
Specific alert text (Filter or Maintenance Timer)
For Heat Pump systems only: "EHEAT"
emergency heat mode active
Summary of Contents for T-100-R
Page 1: ...T 100 R Operation Guide ...
Page 15: ...www evolvecontrols com ...