8
1. Set time of day:
PROGRAMMING PROCEDURES:
NOTE:
The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated
after the hardness is entered.
STEP 1
– Press
NEXT
and
+
simultaneously for 3 seconds.
STEP 2
–
HARDNESS:
Will not show because the manufacturer programmed the
system to regenerate every 1,000 gallons or every 3 days as the default.
NOTE:
This display will show “–nA– (not available)” if “FILTER” is selected.
Press
NEXT
to go to step 3.
Press
REGEN
if you want to exit.
STEP 3
–
DAYS BETWEEN REGENERATION (DAY OVERRIDE):
The manufacturer
has factory set 6 DAYS as the default. This is the maximum number of days
between regenerations. If this is set to “OFF”, regeneration initiation is based
solely on gallons used. If any number is set (allowable range from 1 to 28), a
regeneration initiation will be called for on that day even if a sufficient number
of gallons were not used to call for a regeneration.
Set Day Override using
+
or
—
buttons (6 is recommended):
• set number of days between regeneration (1 to 28); or
•
set
to
“OFF”
2. Programming:
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an
extended power outage occurs, the time of day will flash on and off indicating that the time should be reset.
STEP
1
– Press
SET
CLOCK
.
STEP
2
–
CURRENT TIME (HOUR):
Set the hour of the day using
+
or
—
buttons. AM/PM toggles after 12.
Press
NEXT
to go to step 3.
STEP 3
–
CURRENT TIME (MINUTES):
Set the minutes using
+
or
—
buttons. If it is desired to back up to the
previous step press
REGEN
button once. Press
NEXT
to go to step 4.
STEP
4
–
CURRENT DAY:
Set the day of the week using
+
or
—
buttons. Pressing
NEXT
will exit
SET
CLOCK
and
return to the general operating display (page 9).
WATER HARDNESS
SET
GR
-nA-
1
2
TIME
HOUR
SET
2:00
AM
2
TIME
MINUTES
SET
2:10
AM
3
CURRENT DAY
SET
MON
4
1
DAYS BETWEEN REGEN
SET
6
3