Evolve EACG Installation Instructions & Owner'S Manual Download Page 11

11

 OPERATING DISPLAYS AND INSTRUCTIONS:

The air sulfur and air iron filter systems look and function much like any backwashing whole house filter; however, 
unlike these conventional filters, they use air as a regenerant. This atmospheric air (containing oxygen) helps convert 
iron or hydrogen sulfide into particles. These filters capture the particles of iron or hydrogen sulfide gas within the filter 
media. Your dealer has recommended the proper media depending on your local water conditions. In some cases 
where an acidic water condition (low pH) is present, the media may need to be periodically replenished if using this 
filter to raise the pH to an acceptable level. Consult dealer for this service. The system is prefactory set to regenerate 
every (3) three days at midnight. The frequency and start time of backwash/regeneration is adjustable to meet local 
operating conditions and contaminant levels. Total backwash and recharge time is normally one half hour.

     

1.  

GENERAL OPERATION:

 

When the system is operating, one of five displays may be shown and will alternate with the 

installing dealer’s name and phone number for future service. Pressing 

NEXT

 will alternate between the displays. 

 1. 

 CURRENT TIME OF DAY

 and 

GPM

 2. 

 FLOW RATE

 which is the current treated water flow rate through the system in Gallons Per Minute

 3. 

 VACATION MODE 

allows the system to be “shut down” when there will be no water usage for an extended 

period of time

 

4.  CAPACITY REMAINING

 which is the gallons that will be treated before the system signals a regeneration cycle

 5. 

 DAYS TO A REGEN

 is the number of days left before the system goes through a regeneration cycle, based on 

the days override value

 6. 

 DEALER NAME AND PHONE NUMBER

 is the dealer information to call when service is needed (this screen will 

only appear if set by dealer)

1

TIME OF DAY

MON

GPM

2:40

8

PM

2

FLOW RATE

GPM

8.0

5

DAYS TO A REGEN

GPM

3

8

6

PHONE NUMBER

DEALER NA

The user can scroll between the displays as desired.

 
     If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN 

TODAY” will appear on the display.

     If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons per 

minute going through the system.

2. 

 VACATION MODE:

 

This feature may be used to “shut down” the system while on vacation. The manufacturer has 

factory set “OFF” as the default. Turn feature “OFF” or “ON” using the 

+

 or 

 buttons. When turned “ON”, the 

unit will not regenerate while there is no water usage. Once water usage is observed (minimum of 50 gallons), the 
unit will automatically regenerate that night and resume normal operation.

CAUTION:

  Depending on the severity of water conditions and the length of no water 

usage, it may not be recommended to use this feature. Please contact 
dealer or manufacturer for more information.

3.  

REGENERATION MODE:

 

Typically a system is set to regenerate at a time of no 

water usage. If there is a demand for water when the system is regenerating, untreated 
water will be delivered. When the system begins to regenerate, the display will include 
information about the step of the regeneration process and the time remaining for that 
step to be completed. The system runs through the steps automatically and will reset 
itself to provide treated water when the regeneration has been completed.

3

ON VACATION

NO

4

CAPACITY REMAINING

GPM

GAL

1600

8

BACKWASH

8:22

REGENERATION MODE

Summary of Contents for EACG

Page 1: ...Evolve Series Water Filters For Models EVFE EVS EAG EACG EVBF EVBF AN...

Page 2: ...ase study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner conta...

Page 3: ...y Remaining and Days to a Regeneration are optional displays but are not normally used Vacation Mode is used only when there will be no water usage for an extended period of time If activated once 50...

Page 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Page 5: ...een its outlet and the inlet of a water heater CAUTION To protect the unit in the event of a hot water heater backup the manufacturer recommends the use of an expansion tank on the outlet side of the...

Page 6: ...control fitting and solder joints Failure to do this could cause interior damage to the flow control Backwash of an automatic filter can be directed into a septic tank in most cases but because of th...

Page 7: ...neration which comes into contact with the chlorine pellets dissolves them and is then drawn into the filter to disinfect the system periodically and then safely rinsed away We recommend the use of pe...

Page 8: ...alled for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons 6 is recommended set number of days between regeneration 1 to 28...

Page 9: ...r Press NEXT three times to advance past this screen STEP 7 SERVICE ALARM TIME The manufacturer has factory set OFF as the default This feature is used to signal service into the future This is typica...

Page 10: ...hing and holding the REGEN button for three seconds while in the Backwash Air cycle will skip the remaining mini steps and proceed to the next cycle of regeneration which is usually Backwash The syste...

Page 11: ...goes through a regeneration cycle based on the days override value 6 DEALER NAME AND PHONE NUMBER is the dealer information to call when service is needed this screen will only appear if set by dealer...

Page 12: ...e based on gallons or time To turn off alarm If the audible alarm sounds press any button on the face of the control valve to turn off and call the dealer for service To reset Both the gallon alarm se...

Page 13: ...Do not overfill The additional media added should not be higher than two thirds of the tank height when measuring from the bottom see diagram Once the right height has been achieved replace top fill p...

Page 14: ...board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed...

Page 15: ...in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Contro...

Page 16: ...r 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap...

Page 17: ...on A Drive bracket not snapped in properly and out enough that reduction gears and drive gear do not interface A Snap drive bracket in properly then Press NEXT and REGEN buttons for 3 seconds to resyn...

Page 18: ...power supply from PC board for 5 seconds and then reconnect 20 Err 109 A Invalid motor state detected A Replace PC board 21 Err 201 A Invalid regeneration cycle step detected A Replace PC board 22 Err...

Page 19: ...acket spring clip 1 4 CV3502WE Evolve PC board used on chlorine generator models 1 CV4022WU Evolve PC board standard 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV3002CC Drive assemb...

Page 20: ...assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 CV3358 O ring 219 1 25 distributor 8 CV3556 Screw 1 4 20x1 1 2 18 8SS...

Page 21: ...Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV3152 O...

Page 22: ...or assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN not shown CV3170 O ring 0...

Page 23: ...CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162 042 4 2 DLFC for 3 4 elbow CV3162 053 5 3 DLFC for 3 4 elbow CV3162 065 6 5 DLFC for 3 4 e...

Page 24: ...1 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve the...

Page 25: ...CHLORINE TANK ASSEMBLY Item No Part No Description Qty 1 CH4600 50 474 safety float valve 1 2 CH4640 32 474 float assembly 1 3 CH4500 48 474 air check 1 4 CN1043 10 pad for feeder 1 5 CH7001 Grid for...

Page 26: ...Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2...

Page 27: ...Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assem...

Page 28: ...Plus Calcite Greensand Plus Calcite Greensand Plus Calcite 1 Amount Cu Ft 1 0 1 5 2 0 1 0 1 5 2 0 Gravel Amount Size No 1 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 21 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1...

Page 29: ...1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 7 lb 20 Continuous Flow GPM 5 0 5 0 6 0 6 0 7 0 11 0 Peak Flow GPM 8 0 9 0 12 0 10 0 11 0 18 0 Back...

Page 30: ...expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and conditio...

Page 31: ...water REGEN TODAY MON GPM 2 40 8 PM REGEN TODAY and TIME OF DAY will flash alternately if a regeneration is expected tonight NORMAL OPERATION BYPASS OPERATION QUICK REFERENCE GUIDE GENERAL OPERATION...

Page 32: ...ress NEXT 8 Adjust time of regeneration minutes with and buttons 9 Press NEXT 10 Turn service alarm time ON with and buttons Default is OFF 11 Press NEXT twice 12 Turn service alarm gallons ON with an...

Reviews: