TABELLA 2 

– TABLE 2 – TABLEAU 2 – TABELA 2 – TABLA 2 – TABELLE 2 – TABEL 2 – 

2

 لودجلا

 

ITALY 

 

Iniettori 

bruciatore 

princip. Ø1/100 

mm 

Iniettori spia 

N° 

By-pass 

Ø 1/100 mm 

Pos. aria primaria bruciatore 

principale m

isura “x” in mm 

BRUCIATORE C                           PORTATA NOMINALE   kW 6,0           PORTATA RIDOTTA   kW 1,3 

Gas liquidi (G30 28...30mbar) 

110 

20 

45 

20 

Gas naturali (G20 20mbar) 

185 

35 

Regolabile 

BRUCIATORE D                      PORTATA NOMINALE   kW 10,0          PORTATA RIDOTTA   kW 3,0 

Gas liquidi (G30 28...30mbar) 

140 

20 

75 

20 

Gas naturali (G20 20mbar) 

235 

35 

Regolabile 

BRUCIATORE FORNO SERIE  700/900         PORTATA NOMINALE   kW 7,7          PORTATA RIDOTTA   kW / (ON 

– OFF) 

Gas liquidi (G30 28...30mbar) 

135 

24 

Aperta 

Gas naturali (G20 20mbar) 

201R 

29.2 

Aperta 

BRUCIATORE FORNO MAXI SERIE  700/900         PORTATA NOMINALE   kW 9,2          PORTATA RIDOTTA   kW / (ON 

– OFF) 

Gas liquidi (G30 28...30mbar) 

155R 

24 

Aperta 

Gas naturali (G20 20mbar) 

235R 

29.2 

Aperta 

GREAT BRITAIN 

 

Main burner 

injectors

 

Ø 1/100 mm 

Pilot light 

injectors

 

No.

 

By-pass 

Ø 1/100 mm 

Main burner primary air pos. 

size “x” in mm 

BURNER C                 NOMINAL CAPACITY  kW 6,0           REDUCED CAPACITY  kW 1,3 

Liquid gases (G30 

– G31) 

110 

20 

45 

20 

Natural gases (G20) 

185 

35 

Adjustable 

BURNER    D                NOMINAL CAPACITY   10,0 kW           REDUCED CAPACITY  3,0 kW 

Liquid gases (G30 

– G31) 

140 

20 

75 

20 

Natural gases (G20) 

235 

35 

Adjustable 

OVEN BURNER SERIES 700/900           NOMINAL CAPACITY   7,7 kW         REDUCED CAPACITY  kW / (ON 

– OFF) 

Liquid gases (G30 

– G31) 

135 

24 

Open 

Natural gases (G20) 

201R 

29.2 

Open 

OVEN BURNER MAXI SERIES 700/900           NOMINAL CAPACITY   9,2 kW           REDUCED CAPACITY  kW / (ON 

– OFF) 

Liquid gases (G30 

– G31) 

155R 

24 

Open 

Natural gases (G20) 

235R 

29.2 

Open 

FRANCE - BELGIQUE

 

 

Injecteurs Brûleur 

Principal Ø 1/100 

mm 

Injecteurs 

veilleuse

 

 

By-pass 

Ø 1/100 mm 

Posit. air primaire brûl. 

principal 

dimension “x” en mm 

                                                    BRÛLEUR C             DÉBIT NOMINAL   kW 6,0          DÉBIT MINIMUM   kW 1,3 

Gaz liquides (G30 28...30mbar) 

110 

20 

45 

20 

Gaz naturels (G20/25) 

185 

35 

Réglable 

BRÛLEUR D             DÉBIT NOMINAL   kW 10,0              DÉBIT MINIMUM    kW   3,0 

Gaz liquides (G30 28...30mbar) 

140 

20 

75 

20 

Gaz naturels (G20/25) 

235 

35 

Réglable 

BRÛLEUR FOUR SÉRIE 700/900           DÉBIT NOMINAL kW  7,7            DÉBIT MINIMUM kW / (ON 

– OFF) 

Gaz liquides (G30 28...30mbar) 

135 

24 

Ouverte 

Gaz naturels (G20/25) 

201R 

29,2 

Ouverte 

BRÛLEUR FOUR MAXI SÉRIE 700/900           DÉBIT NOMINAL  kW  9,2          DÉBIT MINIMUM kW / (ON 

– OFF) 

Gaz liquides (G30 28...30mbar) 

155R 

24 

Ouverte 

Gaz naturels (G20/25) 

235R 

29,2 

Ouverte 

DEUTSCHLAND 

 

Düsen 

Hauptbrenner 

Ø 1/100 mm 

Kontrolldüsen

 

Stck.

 

By-pass 

Ø 1/100 mm 

Pos. Primärluft Hauptbrenner 

Maße “x” in mm 

BRENNER    C               NENNWÄRMEBELASTUNG   6,0 kW           REDUZIERTE NENNWÄRMEBELASTUNG    1,3 kW 

Flüssiggas (G30  50mbar) 

95 

20 

45 

20 

Erdgas (G20   20mbar) 

185 

35 

Einstellbar 

BRENNER    D               NENNWÄRMEBELASTUNG   10,0 kW           REDUZIERTE NENNWÄRMEBELASTUNG    3,0 kW 

Flüssiggas (G30  50mbar) 

125 

20 

75 

20 

Erdgas (G20   20mbar) 

235 

35 

Einstellbar 

BACKOFENBRENNER  SERIE  700/900        NENNWÄRMEBELASTUNG 7,7 kW      REDUZIERTE NENNWÄRMEBELASTUNG  

kW / (ON 

– OFF) 

Flüssiggas (G30  50mbar) 

120 

24 

Auf 

Erdgas (G20   20mbar) 

201R 

29.2 

Auf 

BACKOFENBRENNER MAXI SERIE 700/900     NENNWÄRMEBELASTUNG 9,2 kW    REDUZIERTE NENNWÄRMEBELASTUNG 

kW / (ON 

– OFF) 

Flüssiggas (G30  50mbar) 

135R 

24 

Auf 

Erdgas (G20   20mbar) 

235R 

29.2 

Auf 

ESPAÑA 

 

Inyector 

Quemador 

Inyectores 

piloto 

By-pass 

Ø 1/100 mm 

Aire Primario 

desde 

“x” mm 

Summary of Contents for E70CBG02

Page 1: ...LAS INSTRUCCIONES ANTES DE USAR EL APARATO CUCINE A GAS GAS RANGES CUISINIÈRES À GAZ GASHERDE COCINAS A GAS EVOLVE LIBRETTO DI ISTRUZIONI D USO E MANUTENZIONE CUCINE A GAS INSTRUCTIONS USE AND MAINTENANCE HANDBOOK GAS RANGES NOTICE D INSTALLATION D EMPLOI ET DE MAINTENANCE CUISINIÈRES À GAZ BEDIENUNGS UND WARTUNGSANLEITUNG GASHERDE MANUAL DE ISTRUCCIONES DE USO Y MANTENIMIENTO CUCINAS A GAS Cod 88...

Page 2: ...ente per l installatore abilitato 6 6 1 Valvola gas del forno 6 6 2 Rubinetto gas dei bruciatori del piano di cottura 6 7 ISTRUZIONI D USO 6 7 1 Accensione e spegnimento 6 7 1 1 Fuochi vivi Fig 9 6 7 1 2 Bruciatore del forno Fig 10 7 8 MANUTENZIONE 7 English 7 1 GENERAL INSTRUCTIONS 7 2 INSTALLATION 7 2 1 Installation of the appliance 7 2 2 Installation 7 2 3 Fumes extraction 8 2 4 Connecting up g...

Page 3: ...glage des minimums Fig 6 11 5 2 Changement des injecteurs du four 11 5 2 1 Veilleuse Fig 7 11 5 2 2 Brûleur principal Fig 8 11 6 ACCESSIBILITÉ ET DÉMONTAGE DES PIÈCES réservé à l installateur agréé 11 6 1 Valve gaz du four 11 6 2 Robinet gaz des brûleurs du plan de cuisson 11 6 3 Bougie d allumage du four 11 7 MODE D EMPLOI 11 7 1 Allumage et extinction 11 7 1 1 Feux vives Fig 9 11 7 1 2 Brûleur d...

Page 4: ...probación del quemador principal 15 5 REGULACIÓN PARA EL FUNCIONAMIENTO CON OTROS TIPOS DE GAS 15 5 1 Sustitución de los inyectores de los quemadores principales 15 5 1 1 Llama piloto Fig 3 15 5 1 2 Quemador principal Fig 4 15 5 1 3 Regulación del mínimo Fig 6 15 5 2 Sustitución del inyector del horno 15 5 2 1 Llama piloto Fig 7 15 5 2 2 Quemador principal Fig 8 15 6 ACCESIBILIDAD Y DESMONTAJE DE ...

Page 5: ...e che ritiene utili o necessarie senza pregiudicarne le caratteristiche essenziali La ditta costruttrice declina ogni e qualsiasi responsabilità qualora non venissero strettamente osservate le norme contenute in questo manuale La ditta costruttrice dell apparecchio declina ogni responsabilità per danni causati da errata installazione manomissione dell apparecchio uso improprio cattiva manutenzione...

Page 6: ... La distanza prevista per la regolazione dell aria primaria per i bruciatori del piano di cottura è mostrata nella figura 4 ed indicata nelle tabelle 2 Svitare l iniettore E con una chiave di 11 mm e montare l iniettore previsto controllare la distanza esatta X per l aria 5 1 3 Regolazione dei minimi Fig 6 Togliere la manopola e regolare la fiamma in posizione minimo fino ad ottenere una fiamma st...

Page 7: ...case of a fault or malfunctioning For any repairs only contact an authorised technical service centre and request the use of original spare parts Failure to observe the above may jeopardise safety of the equipment Connection installation of the system and appliances ventilation and fumes extraction must be carried out according to the manufacturer s instructions by professionally specialised staff...

Page 8: ... 3 Regulating the pilot flame Regulate and check that the flame envelops the thermocouple and that the appearance of the same is correct If this is not the case check that the injectors mounted are the right ones see tables 2 4 4 Checking the main burner Switch on the appliance and check that the flame lighting and regulation of the minimum are correct Otherwise the injectors and the position of t...

Page 9: ...tioning close the gas main and call the technical assistance service All maintenance and repair work must be carried out by a qualified technician Français 1 AVERTISSEMENTS GENERAUX Lire attentivement les avertissements contenus dans cette notice dans la mesure où ils fournissent d importantes indications concernant la sécurité d installation d utilisation et d entretien Conserver cette notice de ...

Page 10: ...es sur l appareil sont prévues pour le type de gaz disponible Contrôler sur les données reportées sur la plaquette technique que le débit du réducteur de pression est suffisant pour l alimentation de l appareil Contrôler sur les données reportées sur la plaquette technique que le débit du réducteur de pression est suffisant pour l alimentation de l appareil Eviter d interposer des réduction de sec...

Page 11: ...thermostat jusqu au point d arrêt appuyer sur le bouton d allumage L et en même temps presser plusieurs fois le bouton N Garder le bouton d allumage L poussé à fond pendant quelques instants afin de permettre le chauffage du thermocouple puis le relâcher La veilleuse pourra être observée à travers le regard prévu à cet effet Si après avoir relâché le bouton d allumage la veilleuse s éteint il est ...

Page 12: ... ausschließlich von qualifizierten Fachkräften unter Berücksichtigung der geltenden Normen vorgenommen werden Die Gasanlagen die elektrischen Anlagen und die Räume in denen die Geräte aufgestellt werden müssen den für die unterschiedlichen Bereiche geltenden Vorschriften entsprechend ausgelegt sein Insbesondere ist darauf zu achten dass die für die Verbrennung erforderliche Luft der Brenner 2 m3 h...

Page 13: ...T UND DEMONTAGE DER TEILE Darf nur von einer dazu befähigten Fachkraft vorgenommen werden 6 1 Gasventil des Backofens Die beiden Befestigungsschrauben ausschrauben und die vordere rechte Platte entfernen hierzu sind die Befestigungsstifte zu lösen Die Muttern der Gasrohrleitungen sowie die Mutter des Thermoelements ausschrauben Den Temperaturfühler aus seinem sich im Backraum befindlichen Sitz her...

Page 14: ...ada a un sistema efectivo de toma de tierra tal y como prevén las actuales normativas de seguridad para instalaciones eléctricas Deberán verificarse las exigencias básicas de seguridad y en caso de duda deberá solicitarse una inspección minuciosa del sistema por parte de profesionales debidamente cualificados El fabricante no podrá ser considerado responsable por ningún daño relacionado con un fal...

Page 15: ...e la puerta frontal 4 2 Regulación del aire primario El aire primario debe regularse teniendo en cuenta las indicaciones de las tablas 2 4 3 Regulación de la llama piloto Regule la llama y compruebe que envuelve el termopar y que su aspecto es correcto En caso contrario compruebe que los inyectores instalados son los adecuados consulte las tablas 2 4 4 Comprobación del quemador principal Conecte e...

Page 16: ...ión adecuada El mando del termostato está graduado del 1 al 8 n 1 100 n 2 135 n 3 170 n 4 200 n 5 235 n 6 270 n 7 300 n 8 340 El ajuste del termostato conlleva el encendido y apagado automático del quemador principal ajuste on off sin mínimo Si el mando del termostato se gira a la derecha hasta su tope el quemador principal se apaga y únicamente permanece encendida la llama piloto 7 1 2 3 Apagado ...

Page 17: ...CITY kW ON OFF Liquid gases G30 G31 155R 24 Open Natural gases G20 235R 29 2 Open FRANCE BELGIQUE Injecteurs Brûleur Principal Ø 1 100 mm Injecteurs veilleuse N By pass Ø 1 100 mm Posit air primaire brûl principal dimension x en mm BRÛLEUR C DÉBIT NOMINAL kW 6 0 DÉBIT MINIMUM kW 1 3 Gaz liquides G30 28 30mbar 110 20 45 20 Gaz naturels G20 25 185 35 Réglable 7 BRÛLEUR D DÉBIT NOMINAL kW 10 0 DÉBIT ...

Page 18: ...نيف تدفق Wk 3 انخفاض تدفق معدل Wk 10 الغاز سوائل G30 28 30mbar 140 20 75 20 طبيعي غاز G20 20mbar 235 35 للتعديل قابل 4 تصنيف تدفق Wk 7 7 انخفاض تدفق معدل FFO NO Wk فرن الموقد الغاز سوائل G30 28 30mbar 135 24 فتح طبيعي غاز G20 20mbar 201R 29 2 فتح تصنيف تدفق Wk 9 2 انخفاض تدفق معدل FFO NO Wk الموقد الفرن ماكسي سلسلة الغاز سوائل G30 28 30mbar 155R 24 فتح طبيعي غاز G20 20mbar 235R 29 2 فتح TABELLA 3 ...

Page 19: ... max Flüssiggas G20 20 17 25 Flüssiggas G25 20 17 25 Erdgas G30 G31 50 50 42 5 42 5 57 5 57 5 PORTUGAL Pressão de alimentação mbar Tipo de gás nominal mínima máxima Gás natural metano G20 20 17 25 Gás líquido GPL G30 31 28 30 37 20 25 35 45 BELGIEN Förderdrucks mbar Gas nominal min max Erdgas G20 G25 20 25 17 20 25 30 Flüssiggas G30 G31 28 30 37 20 25 35 45 NEDERLAND Toevoerdruk mbar Type gas nomi...

Page 20: ...URINER RIAR BURINER OFF PILOT MAX MIN BRÛLEUR AVANT BRULEUR ARRIER ETEINT PILOT MAX MIN VORAUSBRENNER HINAUSBRENNER LOSCHEN PILOTA MAX MIN QUEMADOR FRENTE QUEMADOR TRASERO OFF PILOT MAX MIN QUEIMADOR ANTERIOR QUEIMADOR POSTERIOR APAGADO PILOTO MAX MIN VOORBRANDER ACHTERBRANDER OFF PILOT MAX MIN األمامية الخلفية قبالة متسابق دقيقة ماكس Fig 8 Abb 9 الشكل 9 Fig 9 Abb 10 الشكل 10 Fig 10 Abb 11 الشكل 1...

Page 21: ...räts von Seiten des Besitzers hat die Verhängung der von den geltenden Normen vorgesehenen Verwaltungsstrafen zur Folge Aplicación de las Directivas 2002 95 CE 2002 96 CE y 2003 108 CE sobre las restricción del uso de sustancias peligrosas en equipos eléctricos y electrónicos además de la eliminación de residuos El símbolo del contenedor tachado del aparato o el envase indica que el producto al fi...