4.0 ELECTRICAL CONNECTION
4.1.1 Employ a competent electrician to ensure wiring installation is made in accordance
with any local electrical codes. Every motor requires either a fused disconnect
switch or a circuit breaker.
4.1.2 Check that the information on the nameplate corresponds to the power supply.
4.1.3 A single phase motor has a built in thermal overload switch.
5.0 PRIMING
5.1.1 The pump will prime and re prime providing the hair and lint pot bowl is full of water
and there is sufficient supply from the suction point.
5.1.2 If you lose water from the hair and lint pot bowl it will be necessary to re fill it before
starting.
5.1.3 Remove the clear lid and fill the hair and lint pot bowl with water. Replace the lid
ensuring the o-ring is correctly located and start the pump.
5.1.4 After you have done this allow a few minutes (maximum) for the pump to start
delivering water.
5.1.5
!
WARNING:
High suction lift or long suction lines will require additional time to
prime and can severely affect the performance of the pump. If the pump will not
prime (flow), repeat step 1 and 2 above.
5.1.6
!
WARNING:
Mechanical seals if allowed to run dry can be damaged rapidly and
may need to be replaced.
5.1.7 ENSURE that there is always adequate water in the hair and lint pot bowl before
you commence start up.
5.1.8 If you are unable to prime the pump please see the trouble-shooting guide.
5.1.9 Ensure all suction and discharge valves are open before you start the pump,
operating the pump with these valves shut can damage the pump.
Evolution Evoflow Pump Manual
4
2.1.12 This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
2.1.13 The appliance is not intended for use by young children. Young children should be
supervised to ensure that they do not play with the appliance. Cut and fit the pipe
and fittings onto the pump and the Cartridge Filter. REFER to Pump Installation
Manual for correct pump plumbing procedures.
3.0 GENERAL INSTALLATION
3.1.1 The pump must be located as close as practical to the pool. The pump must also
be in a position that enables easy access for periodic servicing.
3.1.2 Care must also be taken to position the pump in an area that is free from flooding in
a well ventilated and dry area (The pump motor cooling fan must have a minimum
clearance of 150mm).
3.1.3
The pump suction line should be not smaller than 40mm (1 1/2”).
3.1.4 The suction line is to have as few bends or elbows as possible. There must not be
an air trap on the suction line.
3.1.5 Use only the pump barrel unions supplied with the pump.
3.1.6 Bolt the pump to the required position (prevent movement).
3.1.7 The pump electrical cable must be wired for the proper voltage and rotation in
accordance with the wiring instructions.
3.1.8 All wiring (electrical) work must be carried out by licensed electricians and must be
installed in accordance to the local codes.
3.1.9 The motor must be grounded.
3.1.10 The weight of the plumbing and fittings is to be independently supported and not
carried by the pump.
3.1.11 The pump motor cooling fan must have a minimum clearance of 150mm.