INSTALLING THE UV BULB

1.

  Remove all packaging from the UV bulb 

(C)

.

2.

   Slide the UV bulb 

(C)

 carefully through the quartz sleeve 

(D)

 that you have 

just fitted and tested, as per the instructions on pages 8 and 14.

3.

    While holding one of the black end caps 

(B) 

gently push the cable through the end cap 

which will make it easier to fit the bulb socket 

(F)

 in step 5.  

IMPORTANT

:

 Do not pull the cable by holding just the bulb socket.

4. 

 Fit the End Cap Flat Washer 

(I)

 over the bulb socket and locate it in the end cap so it 

is seated on the inside lip of the end cap.  

IMPORTANT

:

 Ensure the end cap flat washer is not twisted and it remains in this 

location throughout the installation.

5.

     In no particular order, align the 

UV bulb pins with the holes in 
the bulb socket and carefully 
push the bulb socket firmly onto 
the UV bulb pins. You may need 
to hold the other end of the UV 
bulb to help you fit the socket.

6.

   Ensure the UV bulb socket is 

firmly connected to the UV bulb. 

7.

   Repeat steps 3 to 6 at the other end of the unit.

8.

   Now at one end of the unit, slide the black end cap (checking that the flat washer in 

position) over the bulb socket while carefully holding the cable to prevent the bulb 
connector disconnecting from the UV bulb.  

9.

   Screw this end cap onto the thread on the white locking nut 

(H)

 already connected to 

the UV body. 

HAND TIGHTEN ONLY

.

10.

  Repeat steps 8 and 9 at the other end of the unit.

11.

  Check that all of the fittings are hand tightened. No tools are needed.

12.

   On multiple bulb units, do not mix up the bulb connectors as this will result in the bulb 

not illuminating.

Please ensure that there is enough space at one end of the UV to enable bulb / quartz 
sleeve removal and maintenance.

(B)

(I) (F) (C)

(H)

(D)

HAND TIGHTEN FITTINGS ONLY - DO NOT USE TOOLS

Downloaded from http://www.watergardeningdirect.com

Summary of Contents for evoUV evo110

Page 1: ...before running the unit After replacing bulbs or before tightening the end cap make sure that the O Rings are in the correct position and the bulb sockets are dry If the electrical connections get wet...

Page 2: ...e UV C emitter when it is removed from the appliance enclosure Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV C radiation UV C radiation may even in...

Page 3: ...rs are packed in separate small bags inside the box Stainless steel mounting brackets and screws are also supplied in bags and need to be fitted On the 110 UV the mounting brackets can be found in the...

Page 4: ...eeve O Ring G 2 x End Cap Flat Washer I Round O Ring Flat Washer Description Label Qty Order Code Inlet Outlet 1 Hosetail A 2 HOSETAIL15TH End Cap B 2 EVOCONNUT UV Bulb C 1 Available from your EA deal...

Page 5: ...VOUVORINGHOSET Bulb Socket F 2 LAMPHOLDER T8 Quartz Sleeve O Ring G 2 EVOUVORING2 Locking Nut H 2 EVO M F End Cap Flat Washer I 2 EVOUVFLATWASHER Electrical Box J 1 Available from your EA dealer Cable...

Page 6: ...e from your EA dealer Bulb Socket F 4 LAMPHOLDER T8 Quartz Sleeve O Ring G 4 EVOUVORING2 Locking Nut H 4 EVO M F End Cap Flat Washer I 4 EVOUVFLATWASHER Electrical Box J 1 Available from your EA deale...

Page 7: ...US Gallons 10 000 Litres hr 2 200 UK Gallons hr 2 642 US Gallons hr 25W 1 x 25W T8 1 2 x 1 Threaded Hosetails evo30 30 000 Litres 6 600 UK Gallons 7 925 US Gallons 15 000 Litres hr 3 300 UK Gallons hr...

Page 8: ...leeve are visible at each end of the unit 7 Fit the quartz sleeve O Ring G at the other end of the quartz sleeve again ensuring that equal amounts of quartz sleeve are visible at each end of the unit...

Page 9: ...ckets 110W Stainless steel mounting brackets nuts and bolts can be found inside the packaging On the 110 UV you can find the two mounting brackets inside the cardboard fitting inside the box Nuts and...

Page 10: ...SE NOTE Wall mounting screws and wall plugs are not provided If installing the unit prior to or without a pond filter we would recommend the use of a pre filter on the water pump to prevent excess sol...

Page 11: ...ller sections of the hosetails must be cut off to ensure sufficient water flow and to prevent possible damage to the pump We recommend that you use the largest diameter hose available The hosetails sh...

Page 12: ...ESSURE PIPE SCREW SCREW GLUE GLUE EA CODE K82 23 55 EA CODE K82 78 55 EA CODE U10 050 EA CODE U10 050 1 Straight Connector Converter Threaded Male to Plain Female The unit may also be rigid plumbed to...

Page 13: ...ipe CONNECTION TO IMPERIAL PRESSURE PIPE DO NOT OVERTIGHTEN FITTINGS The evo110 may also be rigid plumbed to 2 Pressure Pipe by the use of adaptors and solvent weld adhesive available from Evolution A...

Page 14: ...leaking STEP 7 If no water leaks quartz sleeve has been properly installed Proceed to connecting the UV to the power supply STEP 2 Check the locking nuts are hand tight only STEP 4 Connect up to pipe...

Page 15: ...must be connected to permanent wiring A switch with 3mm contact separation must be provided in the fixed wiring to provide disconnection from the electricity supply It is recommended that the UV unit...

Page 16: ...o the UV bulb pins You may need to hold the other end of the UV bulb to help you fit the socket 6 Ensure the UV bulb socket is firmly connected to the UV bulb 7 Repeat steps 3 to 6 at the other end of...

Page 17: ...A NEW UV BULB Follow the instructions on page 16 to fit a new UV bulb IMPORTANT After checking all the fittings are correctly tightened you can switch your unit back on As already mentioned it is esse...

Page 18: ...pipework and tilt the unit to drain the chamber of water 7 Clean the sleeve and polish with a soft cloth or paper towel If you live in a hard water area you may get limescale on the quartz sleeve this...

Page 19: ...e thermal overload protection which automatically shuts down and then enables a fast re start when the problem has been cleared This may be as a result of water in the end caps Please see the troubles...

Page 20: ...ou have the right model for your pond size Ensure your pond filtration is removing fish waste and debris efficiently Dirt in ponds will affect the efficiency of the evoUV Check that your pond water vo...

Page 21: ...ter systems Can I use my evoUV if I am using any treatments for my fish Always check the manufacturer s instructions before using any water treatment as they will tell you whether it s recommended tha...

Page 22: ...idental damages and expenses arising from the production sale use or misuse of this product or any other consequential loss Any warranty claim must be accompanied by a valid dated proof of purchase Ce...

Page 23: ...RESS POSTCODE COUNTRY EMAIL MODEL OF EVOUV PURCHASED FROM DATE OF PURCHASE SIGNED DATE If you prefer to post your warranty form complete the details below and send it to Evolution Aqua Kellet Close Wi...

Page 24: ...her product support TECHNICAL ADVICE Read frequently asked questions about Evolution Aqua products FAQS VISIT OUR WEBSITE AND FOLLOW US ON SOCIAL MEDIA For all the latest Evolution Aqua news sign up t...

Reviews: