Evolution Aqua eazypod Installation & Operating Instructions Manual Download Page 5

                                                                       
 5 

Gravity Fed Installation Section  

 

IMPORTANT…

For gravity fed installations, you will need to swap pipes 

D

 and 

E

 for eachother, 

(

no cutting required

) and change the configuration of the inlet, outlet fittings and valves. 

 

 

 

The return pipe 

D

 although crucial for a pump fed system would impede a gravity unit when 

slight fouling of debris occurs in the Pod.  

 

1.

 

Remove the overflow assembly and safely 

store the 3 screws which secure it. Fig. 7 

 

 

2.

 

Remove the stainless steel perforated pipe 

by pulling gently. Fig. 8  

 

 

3.

 

Loosen the upper clip on the rubber                          
 connector Fig. 9        

                                             

 

 

 

 

 

 

    

      Fig. 7                                        Fig.8                                      

                                                                                       

4.

 

Invert the Pod and remove the 2 screws 

and plastic pipe support bracket Fig. 10 

 

 

5.

 

Pull the pipe assembly from the Pod body. 
Fig. 11 

 

                                                                                                  Fig. 9                                      Fig.10 
6.

 NOTE 

 

The return pipe 

D

 is part of a pipe 

assembly comprising of a 90 degree elbow 
and two lengths of pipe. The return pipe 

D

 

(as delivered), is longer than the outlet pipe 

E

Turn the assembly around 180 degrees 

and replace the shorter length as the return 

pipe and the longer length as the exit pipe. 

You have now swapped E for D over for 
each other. 

                                                                                                 

Fig. 11                                    Fig. 12

 

7. The assembly is refitted by pushing the 
shorter pipe through the inverted Pod’s 

central exit hole. Fig. 11 
 
8. Tighten up the rubber connector to form 

a watertight seal, on the now shorter pipe 

D

Fig. 12 
 
9. Refit the steel pipe with the perforations  

at  the top,  

not

 at the bottom. Fig. 13    

 

       Fig. 13                                    Fig 14   

 

 

                                                                  

 

The Pod must be situated at pond water level. That is to say, that when the circulating pump 
is switched off, water is level with the overflow assembly. This level will lower when in 

operation. (see Fig. 14)  

 

The 2 rubber connectors on the inlet and outlet ports must be swapped over so that on the 

inlet you will have the 4 inch (90-115mm) rubber connector 

E

 (Fig.1.1) to take your pipe work 

from the pond and on the outlet you will have the 1.5 inch (40mm) connector for your return 

pressure line.                                                                         

Page 5

Aqua-Mania - www.aqua-mania.org - [email protected] - +34 609934211

Summary of Contents for eazypod

Page 1: ...tion and operation Manufactured by Evolution Aqua Ltd Evolution House Kellet Close Wigan WN5 0LP Tel 44 0 1942 216554 Fax 44 0 1942 216562 Web www evolutionaqua com E mail info evolutionaqua com Paten...

Page 2: ...er holds 30 litres of static K1 media As the water enters the central chamber the fine smaller solids become entrapped in the K1 After passing through the K1 media the clean water then rises and overf...

Page 3: ...ere is used as the only filtration system a total pond volume turn over of every 2 hours is found to be best Therefore if you have a 10 000 litre koi pond a flow rate of 5 000 litres per hour is ideal...

Page 4: ...t an inch from the airline supplied on the Pod Insert this into the hosepipe that connects to the air pump This will help maintain the hosepipe s rigidity when inserting it into the rubber connector a...

Page 5: ...han the outlet pipe E Turn the assembly around 180 degrees and replace the shorter length as the return pipe and the longer length as the exit pipe You have now swapped E for D over for each other Fig...

Page 6: ...her than the 30 litres supplied Cleaning and maintaining the Pod will depend on flow rate feed stocking blanket weed etc A Pod on a summer pond with heavy blanket weed will need more frequent maintena...

Page 7: ...close valve F 7 Open your inlet slide valve G and turn on your circulation pump to refill the Pod 8 When the water level in chamber B is just level with the overflow assembly close the slide valve G o...

Page 8: ...When drained close valve F and open your inlet valve to refill the Pod 9 Allow the K1 to agitate again for a minimum of two minutes 10 Open valve F to drain again If the water in the Pod is still not...

Page 9: ...erful enough or there isn t enough water in the Pod check that you used the cleaning pipe to maintain the level on a pump fed system Check all air fittings and line for leaks Make sure you haven t ina...

Page 10: ...installation or misuse Liability is limited to replacement of the defective parts This guarantee is not transferable It does not affect your statuary rights If there is a warranty issue please contact...

Reviews: