Pump Fed Systems 

(Water pumped into Pod and returned to pond by gravity)

 

 

The Eazy Pod filtration system can be set up in two ways, pump or gravity fed.  
 

Please Note:

 The pump must not be placed on the base of the pond, as failure in the pipe 

work or connectors could lead to complete drainage of the pond. The pump should be 
raised high enough to leave sufficient water for the fish to survive, in the unlikely event that 

this occurs. 

 

Gravity Fed Systems 

(Water gravity fed into Pod and returned to pond by pump)  

  

Gravity feed users please note

, you will have to alter return pipe 

D

…see instructions page 5.    

 
Installation Section 

(Pump + Gravity Fed)

 

 

• Preparation 

• Installation Equipment 

• Pump Fed Installation 

 • Gravity Fed Installation 

 

Preparation 

A base with level solid ground is required. It should be a minimum of 600mm x 600mm, to 
allow easy access to your valves and for maintenance purposes. 

Important

: The Eazy Pod filter needs to be supported evenly on a level base (a paving flag is 

ideal). Failure to do so could cause damage when it is full of water. 

 

Installation Equipment required: 

1. Pond Pump. Please ensure that the pumps maximum actual flow rate is no more than the 
specified limits. 

2. Air Pump for cleaning the Kaldnes K1 media. An Airtech 40 or 40 e is recommended.  

3. A length of garden hose or braided pipe (10 mm inner diameter) to connect your air 
pump to the air ring in the Pod

.

 Tip: When connecting to your air pump, cut an inch from the 

airline supplied on the Pod. Insert this into the hosepipe that connects to the air pump. This 
will help maintain the hosepipe’s rigidity when inserting it into the rubber connector and clip 
supplied with your air pump (Fig. 5 and Fig. 6).

 

 

 
5. Pipe work from the unit’s waste valves to the 
intended discharge point. This can be rigid 

pipe work or a simple flexible hose. 

                                                                                                                       
 

                                                                                                                

Fig. 5                                 Fig.6

                                                  

Pump Fed Installation                                              

 

The Pod comes to you ready for a pump fed installation – all you need to do is fit the rubber 

connector (Fig.1.1)to outlet 

E

.  

The unit should be situated at a height above the pond water level, to allow adequate 
gravity return to the pond (subject to the maximum performance of your chosen pump).  

The gravity return pipe work from the exit point of the Pod to the pond needs to be a 
minimum of 4 inches (90-115 mm external diameter) and should have no restrictions. Great 

care should be taken to ensure that no air locks are created within the gravity return pipe 

work. Downward returns with no bends are recommended. The pipe work from the pond 
pump to the inlet of the Pod will need to be connected to the 1.5 inch (40mm) slide valve 

G

The 4 inch / 90-115 mm (minimum) gravity return pipe work will need to be connected to the 

rubber adaptor 

E

 on the exit point of the Pod. This fitting when first connected to this pipe 

could appear too big (especially 90mm) – it will however reduce with the clip provided and 

make a tight seal – this is done with a screwdriver.  The return pipe is then extended and 
returned to the pond or waterfall as required. 

Page 4

Aqua-Mania - www.aqua-mania.org - [email protected] - +34 609934211

Summary of Contents for eazypod

Page 1: ...tion and operation Manufactured by Evolution Aqua Ltd Evolution House Kellet Close Wigan WN5 0LP Tel 44 0 1942 216554 Fax 44 0 1942 216562 Web www evolutionaqua com E mail info evolutionaqua com Paten...

Page 2: ...er holds 30 litres of static K1 media As the water enters the central chamber the fine smaller solids become entrapped in the K1 After passing through the K1 media the clean water then rises and overf...

Page 3: ...ere is used as the only filtration system a total pond volume turn over of every 2 hours is found to be best Therefore if you have a 10 000 litre koi pond a flow rate of 5 000 litres per hour is ideal...

Page 4: ...t an inch from the airline supplied on the Pod Insert this into the hosepipe that connects to the air pump This will help maintain the hosepipe s rigidity when inserting it into the rubber connector a...

Page 5: ...han the outlet pipe E Turn the assembly around 180 degrees and replace the shorter length as the return pipe and the longer length as the exit pipe You have now swapped E for D over for each other Fig...

Page 6: ...her than the 30 litres supplied Cleaning and maintaining the Pod will depend on flow rate feed stocking blanket weed etc A Pod on a summer pond with heavy blanket weed will need more frequent maintena...

Page 7: ...close valve F 7 Open your inlet slide valve G and turn on your circulation pump to refill the Pod 8 When the water level in chamber B is just level with the overflow assembly close the slide valve G o...

Page 8: ...When drained close valve F and open your inlet valve to refill the Pod 9 Allow the K1 to agitate again for a minimum of two minutes 10 Open valve F to drain again If the water in the Pod is still not...

Page 9: ...erful enough or there isn t enough water in the Pod check that you used the cleaning pipe to maintain the level on a pump fed system Check all air fittings and line for leaks Make sure you haven t ina...

Page 10: ...installation or misuse Liability is limited to replacement of the defective parts This guarantee is not transferable It does not affect your statuary rights If there is a warranty issue please contact...

Reviews: