NO. 

Name 

Function 

Laser aperture 

Laser output, do not look directly into this aperture 

DB25 IN&OUT 

DB25 interface in and out for ILDA mode 

LCD setting panel 

LCD display with function setting buttons 

Function knob 

For X Y invert & size; Sound sensitivity; R, G, B brightness adjustment 

DMX in & out 

3 pin XLR interface for DMX 

Interlock 

Laser output is available only when the interlock is connected.  
It could be used to connect a laser emergency switch. 

Key switch 

Key switch for laser output 

Power ON/OFF 

 

Power in & out 

AC100~240V power input and output sockets. With output feature you can 
connect the device to one another using the input and output sockets. They 
must be the same fixtures. DO NOT mix fixtures. 

 
 
 

This backlighted LCD display indicates the fixture is DMX addressed, the fixture status, set up values ..etc 
 

 
 
 
 
Main Menu 

LCD display panel

 

 

 

First Menu 

Second Menu 

Third Menu 

DMX512 

Running 

A001 (DMX address) 

 

AUTO                    (auto 

running mode) 

Show 

001~010 

 

 

Music                  (sound  Show 

 

Summary of Contents for Infinium 2200 RGB

Page 1: ...2200 RGB User manual Mode d emploi...

Page 2: ...triques Il est important d utiliser le c ble d alimentation secteur fourni c ble avec terre Toujours d brancher l appareil avant une intervention technique ou avant son entretien Ne pas brancher cet a...

Page 3: ...et solide et de dimension ad quate au poids support L appareil doit tre viss au crochet et serr convenablement afin d viter toute chute due aux vibrations produites par la machine en fonctionnement L...

Page 4: ...dangereuses La commande des lasers des classes 3 et 4 doit tre sous la d pendance d une clef de contr le enlev e lorsque l appareil n est pas utilis et d tenue par une personne qualifi e Avertissement...

Page 5: ...mm Angle de projection max 60 Modulation Analogique 128 figures et animations pr enregistr es Classe 4 Scans Galvo 35 kpps 8 Interface ILDA in out Syst me Scan Fail Safety qui teint le LASER automati...

Page 6: ...t en place et tourn e vers ON 8 ON OFF Interrupteur de mise sous hors tension de l appareil 9 Power in out Connecteurs d alimentation lectrique AC100 240V entr e sortie Ne connectez en sortie qu un au...

Page 7: ...onne qualit Utiliser du c ble torsad blind o Connexion du c ble d alimentation secteur La terre ou Earth doit toujours tre connect Les c bles d alimentation doivent tre homologu s et conformes au Stan...

Page 8: ...chaque appareil gr ce au menu Adresse DMX L adresse renseign e est alors l adresse de base adresse partir de laquelle l appareil va r pondre Selon le mode de contr le DMX s lectionn 12 canaux ou 25 ca...

Page 9: ...otation manuelle 128 1 59 Rotation 30 avec changement de vitesse 160 1 91 Rotation 180 avec changement de vitesse 192 2 23 Rotation horaire infinite de lent rapide 224 2 55 Rotation anti horaire infin...

Page 10: ...figure Zoom 128 1 59 Auto zoom de lent rapide 160 1 91 Auto zoom de lent rapide 192 2 23 Zoom selection vitesse 224 2 55 CH9 21 Taille figure 1 255 Taille de la figure CH10 22 Ecriture 1 127 Vitesse d...

Page 11: ...s parties nettoy es o Maintenance DANGER Risque de chocs lectriques Toujours d brancher l appareil avant une intervention technique ou avant son entretien Rappel Il n y a aucune pi ce rempla able par...

Page 12: ...C n 2014 30 EU Dimensions et poids de l appareil seul 238x246x163 mm 8 kg WARNING Before use and before installing this fixture read carefully this user manual and follow the safety precautions listed...

Page 13: ...vice to any dimmer pack To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture Do not look directly at the LASER light beam while the fixture is on Do...

Page 14: ...d owned by a qualified person Disclaimer The use of this device is exclusively for professional activities show and display It is forbidden to allow projecting the beams to the audience and any areas...

Page 15: ...ion DMX ILDA In and out for ILDA interface 13 or 25 DMX channels 128 automatic programs Power supply voltage AC100 240V 60Hz 2 layers housing to protect sensitive components from dust ATS Technology P...

Page 16: ...onnectors in order to connect the controller with the fixture or one fixture to another Connection with the mains The earth has to be connected The device must only be connected with an electric insta...

Page 17: ...ble only when the interlock is connected It could be used to connect a laser emergency switch 7 Key switch Key switch for laser output 8 Power ON OFF 9 Power in out AC100 240V power input and output s...

Page 18: ...Auto Mode You can control the fixtures individually via your DMX controller Just select the fixture address knowing that this address will be the start address 1st DMX channel The Infinium 2200 RGB pr...

Page 19: ...otation from slow to fast CH4 16 X axis rolling 1 127 Manual rolling 128 159 X axis rolling speed select 160 191 192 223 224 255 CH5 17 Y axis rolling 1 127 Manual rolling 128 159 Y axis rolling speed...

Page 20: ...f not check DMX connectors cables to see if link properly o If the DMX LED is on and no response to the channel check the address settings and DMX polarity o If you have intermittent DMX signal proble...

Page 21: ...r consumption 150 W max Outside size and N W 238x246x163 8 kg EN60825 1 2014 application of the European Directives Directive LVD n 2006 95 CE Directive RoHS 2 n 2011 65 UE Directive EMC n 2014 30 EU...

Reviews: