of several W.cm-2 applied for a few seconds. 

 

The access to the laser emission zones should be reported using the signs in accordance with the Ministerial 
Decree of 4 November 1993 "Signs of safety and health in the workplace" and the NF X 08-003 "Symbols 
graphics and symbols - colors and safety signs "of December 1994. This signaling is completed by the words 
of the class of laser product and the instructions provided in the NF EN 60825-1 standard. Such access can 
be controlled, at least when lasers are operating. 

 

Emissions control: the control panel should be placed outside the locations exposed to hazardous emissions. 
The control of lasers in Classes 3 and 4 should be under the control of a key control, removed when the 
device is not in use and owned by a qualified person. 

 

Disclaimer: The use of this device is exclusively for professional activities show and display. 
 
 

 

It is forbidden to allow projecting the beams to the audience and any areas accessible by persons without 
appropriate eye and skin protective items. It is forbidden to use this device for any other purpose than that 
for which it is intended. 

 

It is forbidden to shine any laser beam to the aircrafts. 

 

If the laser is operated in a situation where health or property injury may occur, operation MUST be stopped 
immediately! 
 

Manufacturer and distributors are not responsible for any damages caused by use of  EVOLITE lasers. User is 
responsible for applying conditions of use according to regulations stipulated in in EN60825-1:2014 ,application 
of the  European Directives : 
 
Directive LVD n°2006/95/CE 
Directive RoHS 2 n°2011/65/UE 
Directive EMC n°2014/30/EU

 

 

 

 

DANGER  

AVOID EYE EXPOSURE TO DIRECT OR SCATTERED RADIATION 
 
 

 DANGER 

AVOID SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION 

 
 
 
 
 

Summary of Contents for Infinium 2200 RGB

Page 1: ...2200 RGB User manual Mode d emploi...

Page 2: ...triques Il est important d utiliser le c ble d alimentation secteur fourni c ble avec terre Toujours d brancher l appareil avant une intervention technique ou avant son entretien Ne pas brancher cet a...

Page 3: ...et solide et de dimension ad quate au poids support L appareil doit tre viss au crochet et serr convenablement afin d viter toute chute due aux vibrations produites par la machine en fonctionnement L...

Page 4: ...dangereuses La commande des lasers des classes 3 et 4 doit tre sous la d pendance d une clef de contr le enlev e lorsque l appareil n est pas utilis et d tenue par une personne qualifi e Avertissement...

Page 5: ...mm Angle de projection max 60 Modulation Analogique 128 figures et animations pr enregistr es Classe 4 Scans Galvo 35 kpps 8 Interface ILDA in out Syst me Scan Fail Safety qui teint le LASER automati...

Page 6: ...t en place et tourn e vers ON 8 ON OFF Interrupteur de mise sous hors tension de l appareil 9 Power in out Connecteurs d alimentation lectrique AC100 240V entr e sortie Ne connectez en sortie qu un au...

Page 7: ...onne qualit Utiliser du c ble torsad blind o Connexion du c ble d alimentation secteur La terre ou Earth doit toujours tre connect Les c bles d alimentation doivent tre homologu s et conformes au Stan...

Page 8: ...chaque appareil gr ce au menu Adresse DMX L adresse renseign e est alors l adresse de base adresse partir de laquelle l appareil va r pondre Selon le mode de contr le DMX s lectionn 12 canaux ou 25 ca...

Page 9: ...otation manuelle 128 1 59 Rotation 30 avec changement de vitesse 160 1 91 Rotation 180 avec changement de vitesse 192 2 23 Rotation horaire infinite de lent rapide 224 2 55 Rotation anti horaire infin...

Page 10: ...figure Zoom 128 1 59 Auto zoom de lent rapide 160 1 91 Auto zoom de lent rapide 192 2 23 Zoom selection vitesse 224 2 55 CH9 21 Taille figure 1 255 Taille de la figure CH10 22 Ecriture 1 127 Vitesse d...

Page 11: ...s parties nettoy es o Maintenance DANGER Risque de chocs lectriques Toujours d brancher l appareil avant une intervention technique ou avant son entretien Rappel Il n y a aucune pi ce rempla able par...

Page 12: ...C n 2014 30 EU Dimensions et poids de l appareil seul 238x246x163 mm 8 kg WARNING Before use and before installing this fixture read carefully this user manual and follow the safety precautions listed...

Page 13: ...vice to any dimmer pack To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture Do not look directly at the LASER light beam while the fixture is on Do...

Page 14: ...d owned by a qualified person Disclaimer The use of this device is exclusively for professional activities show and display It is forbidden to allow projecting the beams to the audience and any areas...

Page 15: ...ion DMX ILDA In and out for ILDA interface 13 or 25 DMX channels 128 automatic programs Power supply voltage AC100 240V 60Hz 2 layers housing to protect sensitive components from dust ATS Technology P...

Page 16: ...onnectors in order to connect the controller with the fixture or one fixture to another Connection with the mains The earth has to be connected The device must only be connected with an electric insta...

Page 17: ...ble only when the interlock is connected It could be used to connect a laser emergency switch 7 Key switch Key switch for laser output 8 Power ON OFF 9 Power in out AC100 240V power input and output s...

Page 18: ...Auto Mode You can control the fixtures individually via your DMX controller Just select the fixture address knowing that this address will be the start address 1st DMX channel The Infinium 2200 RGB pr...

Page 19: ...otation from slow to fast CH4 16 X axis rolling 1 127 Manual rolling 128 159 X axis rolling speed select 160 191 192 223 224 255 CH5 17 Y axis rolling 1 127 Manual rolling 128 159 Y axis rolling speed...

Page 20: ...f not check DMX connectors cables to see if link properly o If the DMX LED is on and no response to the channel check the address settings and DMX polarity o If you have intermittent DMX signal proble...

Page 21: ...r consumption 150 W max Outside size and N W 238x246x163 8 kg EN60825 1 2014 application of the European Directives Directive LVD n 2006 95 CE Directive RoHS 2 n 2011 65 UE Directive EMC n 2014 30 EU...