background image

After setting the above color, the LED will show the corresponding color when press the 
button A on the remote(CH-1 matches with button A).  

c).   Under Random mode, the LED will change color freely, the interval is 1s. 

Note:  Under DMX control, the LED's color would be controlled by DMX controller instead of 
this color setting page. 

3

There are four color standby modes, namely CH-1, CH-2, CH-3 and CH-4. Different 

channels match with different button on the wireless remote. 

4

No-fluid protection setting page 

 

When it shows OIL, press ENTER button to set the status of low-fluid protection. 

Press UP button, it will show ON. This means that the low-fluid protection function is 
activated. Press DOWN button, it will be OFF. This means that low-fluid protection function 
is shut off. After setting, press ENTER button again to exit to page OIL. 

 

Machine’s functions

 

This machine supports wireless remote control, DMX control, fluid sensor, stop immediate 
function and LED lights (3W LED, 21 in total). DMX control is prior to wireless remote 
control. Fog duration is about 7S.  

1

 

LED lights instruction 

LED lights are controlled by the digital display and DMX. 

2

Under wireless remote control, LED color is set according to the digital display. The LED’s 

on/off synchronize with the Fog’s on/off.

 

3

Under DMX control, fog and LED are separate. It has 11 channels to control the effects of 

LED lights. Please refer to below DMX instruction for the details. 

4

DMX instruction 

Total 8 DMX channels as below: 

Channel 1:   Fog (0-9) OFF, (10-255) ON. 

Channel 2:   LED red, (0-9) OFF, (10-255) 0-100%. 

Channel 3:   LED green, (0-9) OFF, (10-255) 0-100%. 

Summary of Contents for DF-1500VA

Page 1: ...DF 1500VA Pionowa wytwornica dymu Vertical fog machine INSTRUKCJA OBS UGI USER MANUAL...

Page 2: ...li j w odpowiednio dobranym przez Ciebie kolorze Urz dzenie zosta o wyposa one w technologi immediate stop pozwalaj c na natychmiastowe zatrzymanie emisji DF 1500VA mo na montowa zar wno w pozycji nor...

Page 3: ...nych perfumy benzyna itd p yn w do zbiornika z p ynem 10 W razie uszkodzenia wytwornicy nie nale y jej u ytkowa Od cz zasilanie i skontaktuj si z autoryzowanym punktem serwisowym 11 U ywaj tylko p yn...

Page 4: ...cisk fog na panelu maszyny lub kt rykolwiek z przycisk w pilota aby rozpocz emisj Wy wietlacz MENU pozwala na przechodzenie przez strony ustawie cznie 6 UP zwi ksza warto DOWN zmniejsza warto ENTER we...

Page 5: ...3 Off 3 Wci nij przycisk na nadajniku wytwornica b dzie emitowa mg Nawigacja w menu Wci nij przycisk MENU aby przej przez kolejne funkcje Struktura DMX tryb 8 kana w Channel 1 Wydmuch dymu 0 9 OFF 10...

Page 6: ...Wydajno 900m3 min Zu ycie p ynu 6 3min L Wysoko wydmuchu 6 8m Sterownik bezprzewodowy W 2 Pojemno zbiornika 2 5L Waga 8 7kg Wymiary 408 264 196 mm Budowa wytwornicy 1 Diody 2 Dysza 3 Wej cie DMX 3 pin...

Page 7: ...eratur atomizacji Je li u ywasz niew a ciwego p ynu mo e to prowadzi do niepe nej atomizacji p ynu B Problem z blokad grza ki wylatuj cy nieprzetworzony p yn mo e by symptomem blokady grza ki Przyczyn...

Page 8: ...owerful vertical fog can reach 6 8 meters high More importantly it allows simultaneous fog output and stop via unique immediate stop patented technology Features 1 New added creative patented technolo...

Page 9: ...liquids of any kind oil gas perfume to the fog liquid 10 If something wrong happen while using please stop the fixture immediately cut off the power and check the fog liquid amount fuse power cable an...

Page 10: ...the time you press the button The following parts should be included when you receive the package 1 One DF 1500VA machine 2 One W 2 Wireless Remote Controller 3 One power cord 4 One user manual Opera...

Page 11: ...it is ready Press the on board fog button on the machine s rear panel or the any button on the remote to create fog Instruction to digital display 1 MENU button Press Menu button to change function pa...

Page 12: ...ws CH 1 press ENTER button to set LED color under button one Through UP and DOWN button user can realize the color setting After finished setting press ENTER again to exit to page CH 1 The LED s color...

Page 13: ...it will be OFF This means that low fluid protection function is shut off After setting press ENTER button again to exit to page OIL Machine s functions This machine supports wireless remote control D...

Page 14: ...necting with DMX signal the digital display will only show the address When the machine is heating it will display HEAT Technical Specification Voltage AC 220V 240V 50 60Hz Fuse 8A 250V Power 1500W LE...

Page 15: ...w quality or counterfeit fog fluid low quality fog fluid have more impurities easy to adhere to the pipe wall and hindered First reason Using the low quality or counterfeit fog fluid low quality fog f...

Page 16: ...The more inferior fog fluid the more impurities thus lead to fluid injection or blocked All fog machines need regular maintenance fog machine maintenance cycle for 1 to 2 months time Specific mainten...

Reviews: