evoheat Solace 1.25 Installation & Operation Manual Download Page 8

3. Specifications

3.5.1  Ultra-low noise
       With the advanced air ducting technology and the super quiet cross-flow fan, the unit can 
       operate with ultra-low noise.
3.5.2  Ultra-thin casing
       With the ultra-thin casing of 200mm, which is the result of compact design, the unit can 
       save more space for you when it is compared with the common dehumidifierswith the 
       thickness of 400mm.
3.5.3  Fashionable appearance
       With noble &fashion arc frame and elegant & graceful snow white color, the unit will be 
       perfectly combined with your pool house.
3.5.4  Newly design controller. 
       With simple operating display, the newly developed controller makes the unit operation 
       easier and more user-friendly.

  

3.6.1 The dehumidifier is controlled by a built-in hygrostat set on one side of the unit and 
          the target RH value can be set ranges from 30% to 90%.  
3.6.2 The unit will not start to dehumidify until the actual RH is beyond the setting value.
3.6.3 We recommend that an external hygrostat should be installed to ensure a constant 
          measure of the humidity in the pool area.
3.6.4 The location of hygrostat is as the following Fig.4:

 
   

  

 

3.6 Hygrostat Control

3.5 Product Features

7

Built-in hygrostat

Fig.4

Warm damp air

Warmer & dehumidified air

   3.4 Working Principle:

6

Fig.3

    The unit works by drawing moist air over a refrigerated coil with a small fan. The cold coil of 
the refrigeration device condenses the water, which is removed, then the air is reheated by the 
hot coil. This process works most effectively with higher ambient temperatures with a high 
dew point temperature(Fig.3).

Model

Solace 1.75

Solace 1.25

Length: A 

1300

1500

3.3 Dimensions

  

3.3.1 Model: Solace 1.25/1.75/2.5

  

Fig.2

3. Specifications

1500

Solace 2.5

Summary of Contents for Solace 1.25

Page 1: ...SOLACE SERIES SWIMMING POOL DEHUMIDIFIER Installation Operation Manual...

Page 2: ...nciple 3 5 Product Features 3 6 Hygrostat Control 4 Installation 5 Usage 5 1 Instruction for Operation Panel 5 2 Operation Instruction 6 Maintenance 7 1 PCB I O Port 7 2 Wiring Diagram Safety Precauti...

Page 3: ...truction must be kept carefully and must always accompany the appliance If it is lost or damaged please contact the local technical service center 1 1 Fail to comply with these recommendations will in...

Page 4: ...ated Do not put fingers or others into the fan or evaporator of the unit otherwise harm may be occurred OPERATION PROHIBITION SHUT OFF THE POWER When the unit needs to be moved or installed again plea...

Page 5: ...agent or similarly qualified persons in order to avoid a hazard 7 It is forbidden to poke objects or anything else through the inlet or outlet grills 8 It is forbidden to dispose of or leave in the re...

Page 6: ...20 240V 50Hz 10 36 See nameplate package label R410A 600g See 3 3 Operation Pressure Side High Operation Pressure Side Low Condensation Pipe Diameter 4 4 2 1 16 4 4 2 1 16 Model Rated Capaclty Air Vol...

Page 7: ...mance Curve Solace 2 5 40 35 30 25 20 15 10 5 0 0 0 5 1 0 1 5 2 0 l h C 0 40 RH 2 5 60 RH 80 RH 40 35 30 25 20 15 10 5 0 0 0 5 1 0 1 5 2 0 l h C 0 40 RH 3 5 60 RH 80 RH 2 5 3 0 40 35 30 25 20 15 10 5...

Page 8: ...coil of the refrigeration device condenses the water which is removed then the air is reheated by the hot coil This process works most effectively with higher ambient temperatures with a high dew poin...

Page 9: ...e perfectly combined with your pool house 3 5 4 Newly design controller With simple operating display the newly developed controller makes the unit operation easier and more user friendly 3 6 1 The de...

Page 10: ...as filter cleaning 4 2 Positioning 4 2 1 Avoid installing the unit in proximity to positions subject to exposure to direct sunlight sources of heat in places with oil fumes places subject to high freq...

Page 11: ...6 Attention If the condensation water discharges directly into a container the condensate outlet should above the container to avoid immersing in the container Select a suitable size hose to connect t...

Page 12: ...the target setting value DOWN 10 RH Defrosting Dehumidifying Press this button once to check the target setting value of relative humidity Press it again can decrease the target setting value Tips Wh...

Page 13: ...Set the target value of relative humidity Press or to check the target relative humidity 11 RH RH Actual relative humidity The selected mode RH RH Press or again to change the target relative humidit...

Page 14: ...ction Operation panel will display the failure codes when the unit gets some malfunctions Please refer to page15 to check the meaning of failure codes RH 5 2 3 Dehumidifying mode When the unit is in d...

Page 15: ...an up the unit every six months Please take the following steps to clean up the strainer regularly 1 Pull out the grill A from the upside of it Fig 8 2 After that pull out the grill Fig 9 then lift th...

Page 16: ...urn grille to the original place Fig 14 5 Clean up the unit outer with soft and damp rag Fig 15 To protect the paint coat of the unit please don t use rough sponge or corrosive detergent to do these W...

Page 17: ...roubleshootings High pressure protection Condenser outlet temp overhigh Evaporator outlet temp sensor failure Humidity sensor failure Motor feedback signal failure Evaporator inlet temp sensor failure...

Page 18: ...HUMI01 HUMI02 CN7 EEV PROG1 L N1 N_Comp N_Valve L_Comp Meaning To operation panel Reserved To fan motor DC To evaporator inlet outlet temp sensor To condenser outlet temp sensor To the build in hygro...

Page 19: ...S TEMP2 HUMI01 HUMI02 TEMP 1 EEV CN1 FM PACC1001 t t 5K CdOT t 5K C1 Operation Panel TO POWER SUPPLY HPS CN7 CdOT Condenser OutletTemperature SS Sensitive Switch EvOT Evaporator Outlet Temperature EvI...

Page 20: ...Code 20121115 0004...

Reviews: