c. Ensure sufficient fresh airflow around the unit as per installation instructions. Make sure cold air
discharged from the top of the unit does not recycle back through the heater. Check and clean
the condenser fins if they are dirty or blocked.
d. The unit will periodically defrost when the ambient air temperature is lower than 8 degrees C.
Heater runs continuously
a. Check the set temperature is at your desired level and that the pool water temperature is at or
below this set point.
b. Possible electrical component failure – contact EVOHEAT
Water appearing around unit base
a. Condensation is a normal by product of running a pool heat pump.
b. Possible water leak. Check the discharge for the presence of chlorine. If the water has no chlorine
then it is condensation and is normal. Another method of checking is to turn the heater off and
run the water pump continuously for a period of 2-4 hours. If the water dries out then it was
condensation. If there is a continuous leak contact EVOHEAT for service.
Temperature on controller is different from actual pool temperature
a. Possible temperature drop due to plumbing. Try increasing set temperature to reach your desired
swim temp
b. Possible fouling of sensor or faulty sensor
Error Codes