4. Safety Instructions

Ensure that all safety instructions and recommendations are always adhered to. Failure to comply with these 
recommendations could void the warranty and cause injury or death. 

Installation, repair, or relocations must only be done by a
fully qualified technician.

The Evo270-1 must be installed to conform to all relevant
Australian Standards and Industry Codes including but
not limited to: Electrical & Electrical Safety, Plumbing &
Hot Water Storage, Heat Pump Installation & Operation

A circuit breaker must be installed for the unit.

Ensure the unit has a good power connection and
earthing to avoid the risk of electrical shocks.

Ensure that there are no leaks on both the plumbing and
drainage fittings.

The unit must not be installed near flammable gas or have
flammable aerosols sprayed in the vicinity.

The base that the unit is installed on must be level and
stable.

If the supply cord is damaged, it must be replaced by a
qualified service agent.

This appliance must be installed in accordance with
national wiring regulations.

Installation must also comply with any local, state or
federal codes at the installation site. Failure to comply can
void your warranty, damage your unit or possible cause
injury or death. Plumbing must comply with
AS/NZS3500.4

Before obtaining access to terminals all supply circuits
must be disconnected.

A P&T valve 

MUST 

be installed in the tank. When the

tank pressure reaches 0.85MPa or when the tank
temperature reaches 99°C, the P&T valve will open
automatically so as to reduce the pressure or temperature
decrease.

In the event of the unit malfunctioning, shut off the

 

power supply and contact your supplier or EvoHeat.

In order to use the unit correctly, run the unit at

 

environment temperature 

-5

°C - 4

3

°C

The unit contains sophisticated electronic devices, do

 

not use unsafe water sources such as lake or

 

groundwater.

The unit produces hot water and will also have hot

 

fittings, therefore should not be touched to avoid injury.

Do not drill any fixings or attachments into the outer

 

casing of the tank. Drilling into the outer casing of the

 

tank may damage the heating coil and 

WILL VOID

 

WARRANTY.

If the unit stops and you restart the unit or turn it on

 

manually, the unit will not start to run again for

 

approximately 3 minutes. This is a protection feature to

 

safeguard the compressor.

The handle of the P&T safety valve should be tested

 

once every six months to remove the calcium

 

carbonate deposits and guarantee there is no blockage

 

in the device.

Once installation is complete, check that all

 

connections 

are secure before the power is turned on.

The installer is to explain to the end user how to

 

operate and maintain the unit in accordance with this

 

instruction manual.

Evo Industries Australia Pty Ltd will not be held

 

responsible for any damages or injuries caused by the

 

incorrect installation of this hot water system.

A maintenance programme must be carried out as

 

recommended in this manual to ensure ongoing

 

reliability.

To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and pressure protective 
equipment required by local codes and no less than a combination temperature and pressure relief valve certified by a nationally 
recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the 
requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSIZ21.22. This valve must be 
marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater. Install the valve 
into an opening provided and marked for this purpose in the water heater, and orient it or provide tubing so that any discharge from 
the valve exits only within 6 inches above, or at any distance below, the structural floor, and does not contact any live electrical 
part. The discharge opening must not be blocked or reduced in size under any circumstances. 

Hydrogen gas is produced in a hot water system served by this heater that has not been used for a long period of time (2 weeks or 
more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot 
water faucet be opened for several minutes at the kitchen sink before using any electrical appliance. 

The appliance is fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full 
disconnection under overvoltage category lll conditions, and these means must be incorporated in the fixed wiring in accordance 
with the wiring rules. 

Summary of Contents for Evo270-1

Page 1: ......

Page 2: ...tart Up 6 6 Operation 7 6 1 The Controller 7 6 2 Operating Functions 8 6 2 1 Startup Shutdown 8 6 2 2 Switching Modes 8 6 2 3 Locking the Controller 8 6 2 4 Setting Checking the Target Temperature 9 6 2 5 Hydroboost Setting 9 6 2 6 Force Defrost 9 6 2 7 Sanitech System 10 6 2 8 System Date Time 10 6 2 9 Setting Cancelling Timers 11 6 2 10 Vacation Mode 12 6 2 11 Fan Ventilation Function 12 7 Troub...

Page 3: ...safe and economical hot water all year round Conforms to AS 3498 2009 Australia and New Zealand Measurement conditions Instant heating Ambient air temperature 20 C 15 C water inlet 15 C water outlet 55 C highest setting temperature 75 C Working Temp Range 1 Ambient temperature is 5 C 43 C Heat Pump 2 The max temperature of water tank is 70 Operating parameters The range of the operating water pres...

Page 4: ...d year d Press at any stage to cancel 3 Press until is displayed This will activate Eco Heating Heat Pump only mode and will provide the most efficient heating 4 During periods of unusually high hot water demand such as additional occupants staying with you you can activate High Requirement modeby pressing until is displayed 5 In any event where there is a failure within the system the Electric El...

Page 5: ...d you restart the unit or turn it on manually the unit will not start to run again for approximately 3 minutes This is a protection feature to safeguard the compressor The handle of the P T safety valve should be tested once every six months to remove the calcium carbonate deposits and guarantee there is no blockage in the device Once installation is complete check that all connections are secure ...

Page 6: ...heat resistant and durable Piping for the P T Valve The spec of the valve connecting thread is BSP3 4 internal thread After installation confirm that the drainpipe outlet is exposed in the air When the flexible drainpipe is joined to the pressure relief orifice of this valve ensure that the flexible drainpipe is pointing downwards and exposed in the air 5 2 Handing Transportation The unit should b...

Page 7: ...ces to allow airflow to circulate through the unit it is advised to keep a minimum gap between walls fences etc of 300mm on the air inlet side 500mm on the air outlet side 100mm overhead rear clearance Without sufficient airflow discharged cold air will recirculate into the unit and consequently lower the heating efficiency If the installation location does not comply with these suggested clearanc...

Page 8: ...e water temperature and target temperature The electric heater always will be off INTELLIGENT MODE The unit will automatically judge the operation mode according to the ambient temperature HIGH REQUIREMENT MODE The difference between heating mode and high requirement mode is the delay time of electric heater In the high demand mode the electric heater will start without delay which can help the us...

Page 9: ... for 0 5 seconds in the running screen of the controller to turn the unit off The main display will now show OFF The unit will dim the screen and display the standby screen when the controller has not been touched for a minute Touch the power button to wake it Note The ON OFF button can only be used to turn the unit on off in standby or on the running screen of the controller 6 2 2 Switching Modes...

Page 10: ... 5 Hydroboost Setting Also known as the Electric heater the Hydroboost setting allows higher levels of hot water to be produced When there are high hot water usage requirements such as guests staying this function may come in useful The Hydroboost setting can be turned on when the unit is heating or in standby mode Press once to turn on Hydroboost and press again to shut it off When activated will...

Page 11: ...arameter value as shown in the below table and press the key to open that value Change the value using the up down arrow keys and press the key to save changes Press to exit the menu Description Parameter Default Range Changing these settings may lower or disable the unit s ability to ensure your water is free from bacteria Sanitech Target Temperature g01 70 degrees 30 70 degrees Sanitech Temperat...

Page 12: ...rt up time A and end time B Press to save the setting and exit back to the main interface Press and hold for 2 seconds the timer display will flash When the timer display flashes choose the start up time C and end time D by pressing or and Press to save the setting and exit back to the main interface Example Setting the unit to run from 7 11am 4pm 6pm using Touch mode To cancel a timer once it has...

Page 13: ...ash when it is selected use the arrow keys to select your desired start day then press to save all changes and exit back to the main interface Note Format is mm dd Example The unit will start up on September the 28th 6 2 11 Fan Ventilation Function This function may come in useful if the system is installed inside and the fan settings need to be adjusted to suit ducting or external ventilation The...

Page 14: ...eck or change the anti freeze temp sensor Solar temp failure P034 The solar temp sensor is open or short circuit Check or change the solar temp sensor High pressure protection E01 The exhaust pressure is high high pressure switch action Check high pressure switch and cooling return circuit Low pressure protection E02 The suction pressure is low low pressure switch action Check low pressure switch ...

Page 15: ... MTS Mechanism temperature switch AT Ambient temperature EEV Electronic expand valve SUT Suction temperature AI01 HP HP BRN BLU Y G OUT1 OUT3 OUT4 OUT5 AC N 3 4 3 4 CN5 GND AI05 GND AI04 GND AI03 GND AI02 GND CN1 CN2 12V NET GND GND DI01 GND DI03 GND DI04 GND DI05 GND L1 CC L2 HT 2 2 GND AI06 DI06 GND OUT6 ORG RED 485 B 485 A CN6 OUT2 BTT TTT CT t 5K t 5K 6 8K t 5K t 5K AT t 5K SUT L N BLU RED Y G...

Page 16: ...ith the water heater 8 3 Using the Overheating Protector The overheating protector is used to turn the power off in an emergency or with power supply issues preventing the water from being heated too high A thermal cut out could indicate a possibly dangerous situation Do not reset the thermal cutout until the unit has been serviced by a qualified technician Contact EvoHeat for a service if this oc...

Page 17: ...l clean of the unit with a damp cloth MAJOR FIVE YEAR SERVICE It is recommended a major five 5 year service be conducted on the Evo270 1 Warning Servicing of a water heater must only be carried out by qualified EvoHeat personnel Phone EvoHeat Service on 1300 859 933 for our closest Accredited Service Agent Note The five year service and routine replacement of any components such as the anode and r...

Page 18: ...ned within the i Costs associated with delivery handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site b provide a copy of your receipt as proof of purchase c have completed the online Warranty Registration Form 5 Onsite technical service is available within the ...

Reviews: