EVoCharge EVoInnovate EVO32-300-001 User Manual & Installation Manual Download Page 3

                                                                                           User Manual Rev 1.0 

 

EVoInnovate EVSE User Manual & Installation Guide 
www.evocharge.com 

Repair and Maintenance Clause 

 

All EVoCharge products do not require routine maintenance however, periodic inspections should be conducted 
to ensure that all parts remain in good working order and no damage exists.  Do not attempt to open, 
disassemble, repair, tamper with, or modify any components of the products 

 the products are not user 

serviceable.  Contact EVoCharge for any repairs.   

 

Only licensed electricians can repair or maintain the charging station.  It is forbidden for general users to repair or 
maintain it.  Turn off input power before performing any repairs or maintenance to the charging station. 

  

FCC Declaration of Conformity 

 

This charging station complies with part 15 of the FCC Rules. Changes or modifications the charging 
station not expressly approved by the manufacturer could void FCC compliance. 

 

Operation is subject to the following two conditions: (1) This charging station may not cause harmful 
interference, and (2) this device must accept any interference received, including interference that may 
cause undesired operation. 

OVERALL WARNINGS & CAUTIONS 

 

 
 

 

 

 

 

 

 

 

 

 

WARNING: RISK OF ELECTRIC SHOCK 
Basic precautions should always be followed when using electrical products, including the 
following: 

 

Read all the instructions before using this product. 

 

This device should be supervised when used around children. 

 

Do not put fingers into the EV connector. 

 

Do not uses this product if the flexible power cord or EV cable is frayed, has broken 
insulation, or any other signs of damage. 

 

Do not use this product if the enclosure or the EV connector is broken, cracked, open, or 
shows any other indication of damage. 

 

WARNING: RISK OF ELECTRIC SHOCK 
Improper connection of the equipment grounding conductor can result in a risk of electric 
shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the 
product is properly grounded. 

 

 

 

 

WARNING: RISK OF ELECTRIC SHOCK 

 

Do not touch live electrical parts. 

 

Incorrect connections may cause electric shock. 

WARNING: This equipment is intended only for charging vehicles that do not require 

ventilation during charging. Please refer to your vehicle’s owner’s manual to determine 

ventilation requirements. 

 

Summary of Contents for EVoInnovate EVO32-300-001

Page 1: ...EVoInnovate EVSE Model Numbers EVO32 300 001 EVO32 300 002 User Manual Installation Guide Revision 1 0...

Page 2: ...The information provided in this manual in no way exempts the user of responsibility to follow all applicable codes or safety standards This document provides instructions for the charging station and...

Page 3: ...is device must accept any interference received including interference that may cause undesired operation OVERALL WARNINGS CAUTIONS WARNING RISK OF ELECTRIC SHOCK Basic precautions should always be fo...

Page 4: ...r Robust Construction Certified for Outdoor Use Robust durable design tamper resistant features NEMA 4 certified for outdoor and indoor use Simple Operation No user interface required with EVSE simply...

Page 5: ...in instance where an existing 30A or 20A dedicated circuit is already installed Security and Tamper Feature In addition to the lock screw that secures the EVoInnovate charging station to the wall moun...

Page 6: ...33 ft with EVoReel P N EVO30 201 001 Electrical Circuit Input Power Requirements 208 240VAC 50 60 Hz Circuit Requirement Dedicated Branch Breaker Double pole Circuit Conductors Line 1 Line 2 Earth Gro...

Page 7: ...ting the Charging Station Maximum Current Output Setting Optional 9 Tools Parts Required for Installation 11 Install the Charging Station 11 Input Wiring Connection Optional Hardwire Connection Only 1...

Page 8: ...er as well as the Mounting Fasteners for both the Charging Station Mounting Bracket and Connector Cable Holder these items are packaged within a compartment of the charging station cardboard packaging...

Page 9: ...Charging Station Per National Electric Code NEC requirements 32A Maximum Output Setting Default Factory Setting a DEDICATED CIRCUIT rated for 40A 208 240 VAC 50 60 Hz Single Phase must be used Circuit...

Page 10: ...lt Factory Maximum Current Output Setting is 32A 7 68 kW for use with a 40A or greater Circuit Rating To adjust the Maximum Current Output Setting when using a 30A or 20A Circuit Rating 1 Place the Ch...

Page 11: ...harness to the charging station circuit board and install the charging station font cover using the following torque force to secure the 5 Torx screws Screw Torque M4 16 kgf cm 13 88 lb in CAUTION Th...

Page 12: ...on Heat Shrink Tube x3 For 8 AWG wire Commercially Available Only Required for Optional Hardwire Connection Terminal x3 For 8 AWG wire Commercially Available Only Required for Optional Hardwire Connec...

Page 13: ...M6 tapping screws Supplied b For masonry walls use M6 mechanical screws Commercially available c Use following torque force Screw Torque M6 50 kgf cm 43 4 lb in 1 4 50 kgf cm 43 4 lb in 4 As shown in...

Page 14: ...ing bracket Figure 2 4 Screw locking position 5 For Plug in NEMA 6 50 models Plug in the power cord to the NEMA 6 50 Wall Outlet Receptacle The NEMA outlet should be located no less than 20 26 from th...

Page 15: ...inal heat shrink tube and copper wire 9 Connecting the electrical wiring to the charging station 9 1 Place the Charging Station on a flat surface front cover down with protection under the cover to av...

Page 16: ...Plug Loosen the Strain Relief Fitting for the NEMA 6 50 Plug and Remove the Plug 9 5 Insert the wire end passing through the conduit and insert them into the input wiring hole Use Red wire for L1 Blac...

Page 17: ...ll the charging station font cover using the following torque force to secure the 5 Torx screws Screw Torque M4 16 kgf cm 13 88 lb in Install the Plug and Cable Holder 1 Separate the holder from hook...

Page 18: ...VSE User Manual Installation Guide www evocharge com 17 3 Position the plastic holder insert face up and install into the holder bracket Figure 2 10 Secure the holder 4 Next rotate the holder insert d...

Page 19: ...tighten the 2 lock set Philips screws located at the top of the plastic holder component until snug do not overtighten The screws ensure that the plastic holder component remains secured to the holde...

Page 20: ...d Steady Unrecoverable Fault Red Flashing Recoverable Fault Yellow Steady Out of Service Yellow Flashing Booting Firmware Upgrade in process Note In the instance the Red Steady or Red Flashing Fault l...

Page 21: ...l automatically restart charging when the cause of the temporary error condition returns to normal The status indicator lights remain flashing RED until the error condition is resolved Temporary error...

Page 22: ...f the product components Despite the water resistance of the enclosure when cleaning it is preferred to not direct streams of water at the unit clean with a water damp automotive grade soft cleaning c...

Reviews: