· 13 ·
3. PC Connection
3.1 Things to Know before Connection
Warning
The connected or built-in peripherals with opposite polarities are not allowed.
Warning
The device only operates when connecting with grounded power. No operation is
allowed when the device power is ungrounded or only impedance is grounded.
Warning
Rated voltage of the device in use shall be in accord with power feature of the
product.
Note:
Only the peripheral devices approved for industrial application can be used. When
operating the PC, hot swappable IO modules (USB) can be used. The IO devices
without hot swap function can only be connected when the PC is powered off.
3.2 Product Grounding
Low impedance ground connection is more helpful to release the interference
produced by the external cables, the signal cables or the cables connecting the IO
module to the grounding system.
Ground Terminals
The equipotential bonding terminal
①
on
the device shall be connected with the
cabinet installed with the PC or the
central grounding busbar on the device.
The minimum cross section area of the
cable shall be no less than 2.5mm
2
. The
maximum ground resistance should be no
more than 0.1
Ω
.
Summary of Contents for SY532
Page 1: ...EVOC SY532 便携式加固计算机 Portable Rugged Computer Version C00 ...
Page 34: ...软件介绍 26 EVOC SY532 3 GPIO GPIO 效果图如上图所示 使用方法 默认状态不启用 GPIO 避免用户程序也存在 GPIO 设置时与之冲 ...
Page 40: ...BIOS 功能介绍 32 EVOC SY532 示 各项目合理的范围是 Hour 时 00 23 Minute 分 00 59 Second 秒 00 59 Advanced ...
Page 74: ...尺寸图 66 EVOC SY532 10 尺寸图 10 1 产品外形及安装尺寸图 102 326 7 390 290 单位 mm ...
Page 98: ......
Page 142: ...BIOS Setup 36 EVOC SY532 00 23 Minute 00 59 Second 00 59 Advanced ...