INTRODUCTION

Be sure to read these instructions completely before use.

Thank you for purchasing the Aeroneb

®

Go Nebulizer.

Certain conditions such as asthma, COPD (chronic obstructive 
pulmonary disease) and cystic fibrosis require that prescribed
liquid medication be turned into a fine mist, called an aerosol,
and then inhaled into the lungs. The Aeroneb

®

Go turns liquid

medication into an aerosol, which you can then inhale through
a mouthpiece or an aerosol mask into your lungs.

The Aeroneb

®

Go uses the unique OnQ

Aerosol Generator,

which is unlike any other nebulizer technology available. When
you turn on your nebulizer, OnQ pumps liquid through tiny
holes in a wafer-thin metal plate to create a soft mist aerosol.

The Aeroneb

®

Go, for use by pediatric and adult patients, is 

intended to aerosolize physician-prescribed solutions for 
inhalation that are approved for use with a general-purpose
nebulizer. Designed with your needs in mind, the Aeroneb

®

Go is lightweight, compact and silent. The control module 
operates with three (3) "AA" disposable batteries, or can 
alternatively be powered by the AC/DC Adapter or AC
Controller.

CAUTION:

Federal law restricts this device to sale by or on the

order of a physician.

Operate this unit only as instructed by the Aeroneb

®

Go

Instruction Manual. Thoroughly read and understand the 
information contained in these instructions before using the
Aeroneb

®

Go.

For future reference, SAVE AND REFER TO THESE INSTRUCTIONS.

REPLACEMENT PARTS AND ACCESSORIES

PART REORDER 

NUMBER

7000

Battery Controller with Cable 

21105

7030

Wall Mount Adapter* 

21099

7070

Battery Controller with Cable 

21105

Wall Mount Adapter* 

21099

7090

Battery Control Module 

22213

AC/DC Power Adapter

22215

REPLACEMENT PARTS AND ACCESSORIES FOR ALL MODELS

Medication Cup Cap 

22210

MicroPump with Chamber, Mouthpiece, Reservoir and Cap  22218
Nebulizer Body 

22207

Mouthpiece 22205
Battery Powered Controller Cable 

22201

Mask Connector Elbow (US) 

22203

Dragon Mask

1010M

Carrying Case 

29049

“AA” Battery, each

21120

Instruction Manual* 

22263

PEDIATRIC ACCESSORIES, PACKAGED SEPARATELY

Safari Sam Color Book Kit, each

22316

Safari Sam Color Book Kit, 12/pack

22317

To order replacement parts or accessories, visit your local home

medical equipment dealer or pharmacy.
*Contact your local supplier for reorder number specific for your

geographical region.
If you have any questions or problems regarding your Aeroneb

®

Go nebulizer, contact your local home medical equipment 

dealer or pharmacy.
Your Aeroneb

®

Go was tested and inspected at the factory and is

a premium device that has a life expectancy of at least one year

(730 treatments) with proper care and cleaning. Lack of proper

care and cleaning, disassembly of the retaining ring or misuse 

will void the warranty.

Summary of Contents for Aeroneb Go

Page 1: ...ed or tampered with during the warranty period Shipping charges if any shall be paid by the purchaser NOTE There is no other express warranty Implied warranties including those of merchantability and fitness for a particular purpose are limited to the duration of the express limited warranty and to the extent permitted by law and all implied warranties are excluded This warranty does not cover pro...

Page 2: ...tion Manual Thoroughly read and understand the information contained in these instructions before using the Aeroneb Go For future reference SAVE AND REFER TO THESE INSTRUCTIONS REPLACEMENT PARTS AND ACCESSORIES PART REORDER NUMBER 7000 Battery Controller with Cable 21105 7030 Wall Mount Adapter 21099 7070 Battery Controller with Cable 21105 Wall Mount Adapter 21099 7090 Battery Control Module 2221...

Page 3: ...is manual Never operate this product if any of the parts are not working properly or have been damaged Do not use the Aeroneb Go Nebulizer in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide Do not use the Aeroneb Go Nebulizer with anesthetic breathing systems or lung ventilator breathing systems 17 2 PERFORMANCE Aerosol flow rate Greater than 0 25 mL per minute Resi...

Page 4: ...eat a life threatening condition a backup device is necessary ELECTROMAGNETIC SUSCEPTIBILITY This device meets the requirements of IEC 60601 1 2 which describes requirements for electromagnetic compatibility EMC of medical devices This includes immunity to radio frequency electric fields and electrostatic discharge in addition to the other applicable requirements of the standard Compliance with EM...

Page 5: ...f the low battery power light is flashing Replace the batteries or use the AC Powered Controller Check that the Battery Powered Controller cable is connected properly to the nebulizer and to the Control Module Connect the cable properly to the nebulizer and the Battery Powered Controller Refer to page 7 No visible aerosol when using AC Powered Controller Check that the AC Powered Controller is plu...

Page 6: ...ct is being used to treat a life threatening condition a backup device is necessary In event of loss of electrical power remove the AC Powered Controller cable from the Aeroneb Go Nebulizer Unit and operate with the Battery Powered Controller refer to page 7 Never clean your Nebulizer Unit with solvents chemicals alcohol or abrasive cleaners Do not microwave any parts Do not use brushes sharp tool...

Page 7: ...hirty 30 minutes IV Rinse all pieces thoroughly under running hot tap water V Shake off excess water and allow parts to air dry on a clean dry towel out of the reach of children VI Make certain that all disinfected parts are completely dry before you store them CONTROL lll GERMICIDE If you would like to disinfect your nebulizer you may use the medical disinfectant described below available from yo...

Page 8: ... and Mouthpiece or Mask Adapter and Mask by hand in a solution of warm water and mild liquid dishwashing soap Use soap intended only for washing dishes by hand Do not use dishwasher detergent as it is too abrasive Do not leave parts soaking in soapy water for more than 20 minutes 2 Rinse all pieces thoroughly under running hot tap water Make sure that no soap is left on any of the parts 3 Shake of...

Page 9: ...end of the cable after each use Clean the Nebulizer Unit and associated parts daily NOTE Removal and improper reinsertion of the retaining ring from the underside of the medication cup may cause the unit to leak or malfunction 11 8 CLEANING AND STORING YOUR AERONEB GO TO OPTIMIZE THE PERFORMANCE and life expectancy of your Aeroneb Go device we recommend you follow these cleaning instructions caref...

Page 10: ...O OPERATE WITH AN AC DC POWERED CONTROLLER The nebulizer can be powered directly with an AC Powered Controller NOTE Aerosol mask is not provided 1 Insert the AC Powered Controller cable connector into the back of the Nebulizer Unit by sliding the cable straight up the nebulizer body 2 Plug the AC Powered Controller into a standard AC electrical outlet using the appropriate outlet adapter The green...

Reviews: