CAUTION:

  For  the  installation  of  the  flexible  drain  hose  to  the  fixed  piping, 

please follow local legislation. 

 

 
 

 
 

 

 
 

 
 

 
 

 

 
 

 

maximum 

height 

and 

distance 

of flexible 

drain hose 

 
 

 

 

3.4

 

Pierce a hole (Ø5mm) in the side wall of the salt container for the brine tube. 

The hole should be located approx. 10cm down from the top edge of the salt 
container. After drilling the hole, remove all bits of plastic that have fallen into 

the salt container.  

 
 

 
 

 

 
 

 
 

 

 
 

 
 

 

 
 

 

Summary of Contents for soft duomatik 2

Page 1: ...ner the installation guide has to be read carefully For any disturbances cause by disregarding the instructions evo water doesn t accept liability evo water oHG Falkenstraße 2 72589 Westerheim Tel 49 7333 925710 Fax 49 7333 9257120 www evo water com info evo water com ...

Page 2: ...ement For the protection of the central tax valves from rust sand etc a suitable mudflap or fine filter should be inserted before the arrangement The filter pad of the fine filters should be exchanged according to DINAR DVGW at a distance of 6 months or after soiling Please ensure that no water damages are caused e g by ground expiry The manufacturer is not liable for water damages The food water ...

Page 3: ... REGULATOR 2 VALVE HOUSING 9 HARDNESS REGULATOR 3 RESIN TANK 10 TO BRINE VALVE 4 SALT CONTAINER 11 CONNECTIONS 1 2 3 4 1 5 BRINE VALVE floater 12 TO DRAIN 6 WATER INLET 13 COMMUNICATION TUBES 7 WATER OUTLET 14 TUBES TO BRINE VALVE ...

Page 4: ...B Parts Evo water Duplex 1 BYPASS 9 HARDNESS REGULATOR 2 VALVE HOUSING 10 TO BRINE VALVE 3 RESIN TANK 11 CONNECTIONS 1 2 3 4 1 4 SALT CONTAINER 12 TO DRAIN 5 BRINE VALVE floater 13 COMMUNICATION TUBES ...

Page 5: ...e incoming pressure Do not install the Softener close to a heating source environment temperature must be below 50 C Protect softener and drain 12 against frost Make sure you have the latest installation manual at hand Check with your supplier 3 Installation 3 1 Close main valve and make sure pressure is released from piping This can be done by opening at least one tap 3 2 Check if all communicati...

Page 6: ... the water softener are available in and 1 Caution before installing the softener set the Bypass in bypass mode not in service 3 3 2 Connect both drain outlets 12 to a local drain by means of a 13mm flexible drain pipe as supplied by your local supplier If necessary use a Y piece to connect both drain outlets In order to guarantee that the device will keep on functioning perfectly in the future th...

Page 7: ... maximum height and distance of flexible drain hose 3 4 Pierce a hole Ø5mm in the side wall of the salt container for the brine tube The hole should be located approx 10cm down from the top edge of the salt container After drilling the hole remove all bits of plastic that have fallen into the salt container ...

Page 8: ...e device Please note that the hole for the overflow tap must be situated BELOW the hole for the brine tube 3 6 Connect the brine tube Ø4mm to the quick release coupling of the brine valve Push the tube in as far as possible To install the brine valve open the cover by pressing it gently at both sides Now put the brine valve in position with the top side up Make sure the valve goes all the way down...

Page 9: ...T PLEASE PROCEED TO 3 8 3 8 At the bottom of the container there are two supports which the device will rest on Check the correct location of these supports refer to the image on the right With the round opening nearest to you the arrows should point to the right as in the image on the right ...

Page 10: ...rows on both supports at the bottom of the container 3 10 A hole needs to be drilled in the side wall of the container for the tube which connects the brine valve to the T piece This hole has to be drilled following the instructions in 3 4 Disconnect the tube lead it through the hole and reconnect it to the T piece ...

Page 11: ...lending regulator part number 8 on the illustration on page 1 With the blending regulator you can determine the outgoing hardness Depending on the desired residual hardness set outgoing hardness with a hex key number 5 The setting is proportional i e 1 10 1 5 1 of total incoming hardness Remark always set regulator on both units to the same setting dh ppm dh ppm 9 160 2 22 391 6 10 178 0 23 409 4 ...

Page 12: ... that the partition wall is correctly in place between the small brackets and all the way down to the bottom of the salt container Please refer to the drawing below where it has been coloured in red to make it clearly visible Fill the salt container on both sides of the partition wall Use only specific salt tablets that are suitable for softeners 5 3 A dd water in the salt container until the wate...

Page 13: ...rform a manual regeneration Use a hex key number 5 to turn the program disk PRG manually Turn PRG counter clockwise until it is in above position When the arrow and the small line on the transparent cover reach the area marked by B brining the regeneration will start Immediately the PRG will drop down a little you will be able to see and hear this R stands for refill refilling the container with w...

Page 14: ...ation stage is over 5 6 3 Open a tap behind the softener for several minutes to allow residual water to be flushed from the tubing 5 6 4 Check outgoing hardness with a hardness test kit not supplied by evo water Adjust blending if necessary 5 7 Place the cover on the salt container Connect the overflow tap to the drain 5 8 for Duplex Duet only Place the cover on the container which holds the devic...

Page 15: ... knowledge about hydraulic softeners and domestic plumbing Proper working of the softener will be determined by proper installation An annual control of your Softener will guarantee optimal functioning and a long operating life The EVO WATER oHG is proud of its achievement in having provided in what we believe to be the best softener available today Moreover we are proud to have you as a customer ...