5.
Start up:
5.1
Leave Bypass in “bypass” mode, open main valve and flush for several
minutes in order to avoid impurities from entering the softener. When you do
not use a Bypass, open the main valve slowly as described in
5.4
.
5.2
Before filling the salt container with salt, check that the partition wall is
correctly in place (between the small brackets, and all the way down to the
bottom of the salt container). Please refer to the drawing below, where it has
been coloured in red to make it clearly visible. Fill the salt container on both
sides
of
the
partition
wall.
Use only specific salt tablets that are suitable for softeners.
5.3
A
dd water in the salt
container until the water level is approx. 10cm (4”) high.
(the floater on the brine valve must be afloat)