15
2551988C
Electrical Connections
Risk of Electric shock.
Disconnect the electric supply before starting any works on the unit.
Qualified personnel.
Electrical installation must only be carried out by technical personnel.
Overvoltage or lightning.
The ModuSat unit has no protection against lightning or other overvoltage shocks.
Power supply via un-switched double pole fused connection.
The ModuSat requires a 220/240V (AC) 50Hz mains supply connection through an
un-switched fused connection fitted with a 3 Amp fuse (to BS1632). Extension
cords, multiple plugs, and other adapters must not be used. The device must be
earthed.
Follow the instructions
Any damage caused by an incorrect connection will invalidate the warranty.
Evinox Energy cannot accept any responsibility for incorrect wiring.
The ModuSat wiring board is located within the ModuSat itself under a removable metal cover. To
access the connection board, the full front case cover should be removed. The connection board is
found in the centre of the unit to your left. To take off the cover the retaining screw should be
removed and the cover lifted off.
Removing the Front panel
To access the wiring board, the front panel must be removed.
The front panel is fixed with four screws – two at the top of the unit and
two at the bottom as shown with are.
Untighten the screws and remove the panel pushing it upwards firs and
then removing it towards yourself.
The panel is powder coated stainless steel. Take care when removing and
placing the front panel to ensure the surface is not damaged. Ensure
After the works are finished, place the panel on the unit and tighten the
screws.