E2630-CO 

Rev 14.12.2020 

Specifications

 

Sensor type 

Electrochemical cell 

Sampling method 

Diffusion 

Typical detection range 

0...200 ppm 

0...1000 ppm 

Alarm setpoints 
(release-LOW-HIGH) 

18 - 25 - 125 ppm 

 88 - 125 - 250 ppm 

Response time T90 

< 30 seconds 

Signal update 

Every 1 second 

Sensor lifetime 

> 6 years 

Calibration interval 

6 months 

Power supply  

11...30 VDC, 

 24 VAC or 90...265 VAC as options 

Power consumption 

< 2 VA 

Digital interface 

UART 

Relay outputs 

2 × SPDT, max 5 A, 30 VDC / 250 VAC 

Alarm signaling  

Buzzer 2 kHz, 85 dB; red LED 

LEDs 

 Green/red (operation/fault), red (gas alarm) 

Enclosure 

Grey ABS, wall mount, protection class IP65 

Dimensions 

H90 × W145 × D55 mm (overall dimensions H140 × W145 × D55 mm) 

CE marking 

According to 2014/30/EU and 2014/35/EU, EN 50491-4-1:2012  

EN 61000-6-3:2020, EN 61326-1:2013(EMC, emissions) 

EN 61000-6-1:2019, EN 61000-6-2:2019(EMC, Immunity) 

EN 60079-29-1:2016, EN 60079-29-2:2015 and EN 60079-29-3:2014 

Operating conditions 

-20...50°C, 15...95% RH without condensation, 0,9...1,1 atm; 

Non-ATEX-rated areas 

 Avoid strong mechanical shock, vibrations or EMI Avoid exposure to 

corrosive gases 

 NOTE! The sensor may exhibit sensitivity to acetylene, ethylene, hydrogen, 

and nitric oxide.

 

Summary of Contents for E2630-CO

Page 1: ...Carbon Monoxide Detector E2630 CO User Manual...

Page 2: ...irements 5 Operating conditions 5 Installation guidelines 6 Mounting dimensions 7 Connections 8 Operation 9 Sensor probe handling 10 The electrochemical gas sensor replacement procedures 10 Maintenanc...

Page 3: ...eight 28 Relative gas density to air 0 97 Conversion 1 ppm 1 15 mg m 3 Boiling point 191 5 C Low explosive limit LEL vol in air 12 5 Upper explosive limit UEL vol in air 74 Odor odorless Hazards Highl...

Page 4: ...ng Buzzer 2 kHz 85 dB red LED LEDs Green red operation fault red gas alarm Enclosure Grey ABS wall mount protection class IP65 Dimensions H90 W145 D55 mm overall dimensions H140 W145 D55 mm CE marking...

Page 5: ...c electricity Connection diagrams can be found in the connections section The device might not perform correctly or be damaged if the wrong power supply is connected External circuits connected to the...

Page 6: ...and repair The aforementioned conditions above will affect the coverage area of the device however the coverage area for a detector is usually between 2 5 to 5 meters radius For early leakage detecti...

Page 7: ...E2630 CO Rev 14 12 2020 Mounting dimensions 7...

Page 8: ...m 2 We recommend to strip the wire end by 5 6 mm and use the wire end sleeves To connect the wire loosen the screw insert the wire end into the terminal hole and tighten the screw The outer diameter o...

Page 9: ...gas concentration exceeds the LOW alarm setpoint the bottom red LED starts flashing at a rate of 1 Hz and the relay RE1 switches over The first alarm stops automatically if the gas concentration drop...

Page 10: ...sor Do not remove the filter as it may cause the device to show incorrect values The recommended orientation of the sensor probe is vertical with the sensor tip pointing downwards This prevents the po...

Page 11: ...e Manufacturer with standard gas mixtures before delivery Provided that the sensor is used under moderate conditions field recalibration is recommended every 6 months Please contact your dealer for mo...

Page 12: ...anufacturer will at its option either repair or replace a product that proves to be defective This warranty is void if the product has been operated in conditions outside ranges specified by the Manuf...

Reviews: