E2630-CO 

Rev 14.12.2020 

Maintenance 

Do not perform any maintenance operation with the power on.  

Clean the device with a soft damp cloth. Do not use any abrasive cleaning agents. Do not

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

immerse the device in water or any cleaning media.  

Calibration 

E2630-CO detectors have been calibrated by the Manufacturer with standard gas mixtures

 

 

 

 

   

 

 

 

 

 

 

before delivery. Provided that the sensor is used under moderate conditions, field

 

 

 

 

 

 

 

 

 

 

 

 

recalibration is recommended every 6 months Please contact your dealer for more

 

 

 

   

 

 

 

 

 

 

 

information. 

 

Delivery set 

Carbon Monoxide Detector E2630-CO  

Mounting accessories:  

4 screws and 4 plastic dowel plugs 

 

 

Order code for E2630-CO options 

 

 

 

 

11 

E2630 options  

Order code 

Integrated 90...265 V mains power supply module 

E2630-CO-230 

Integrated 24 VAC power supply module  

E2630-CO-24VAC 

Summary of Contents for E2630-CO

Page 1: ...Carbon Monoxide Detector E2630 CO User Manual...

Page 2: ...irements 5 Operating conditions 5 Installation guidelines 6 Mounting dimensions 7 Connections 8 Operation 9 Sensor probe handling 10 The electrochemical gas sensor replacement procedures 10 Maintenanc...

Page 3: ...eight 28 Relative gas density to air 0 97 Conversion 1 ppm 1 15 mg m 3 Boiling point 191 5 C Low explosive limit LEL vol in air 12 5 Upper explosive limit UEL vol in air 74 Odor odorless Hazards Highl...

Page 4: ...ng Buzzer 2 kHz 85 dB red LED LEDs Green red operation fault red gas alarm Enclosure Grey ABS wall mount protection class IP65 Dimensions H90 W145 D55 mm overall dimensions H140 W145 D55 mm CE marking...

Page 5: ...c electricity Connection diagrams can be found in the connections section The device might not perform correctly or be damaged if the wrong power supply is connected External circuits connected to the...

Page 6: ...and repair The aforementioned conditions above will affect the coverage area of the device however the coverage area for a detector is usually between 2 5 to 5 meters radius For early leakage detecti...

Page 7: ...E2630 CO Rev 14 12 2020 Mounting dimensions 7...

Page 8: ...m 2 We recommend to strip the wire end by 5 6 mm and use the wire end sleeves To connect the wire loosen the screw insert the wire end into the terminal hole and tighten the screw The outer diameter o...

Page 9: ...gas concentration exceeds the LOW alarm setpoint the bottom red LED starts flashing at a rate of 1 Hz and the relay RE1 switches over The first alarm stops automatically if the gas concentration drop...

Page 10: ...sor Do not remove the filter as it may cause the device to show incorrect values The recommended orientation of the sensor probe is vertical with the sensor tip pointing downwards This prevents the po...

Page 11: ...e Manufacturer with standard gas mixtures before delivery Provided that the sensor is used under moderate conditions field recalibration is recommended every 6 months Please contact your dealer for mo...

Page 12: ...anufacturer will at its option either repair or replace a product that proves to be defective This warranty is void if the product has been operated in conditions outside ranges specified by the Manuf...

Reviews: