Product description

E2615 series gas transmitters are easy-to-install and easy-to-use instruments. The devices
utilize novel fully calibrated gas sensors with excellent repeatability, stability, and long
lifetime.

E2615 series provide analog output with user-selectable signal type, 4-20 mA or 0-10 V.

The version of your transmitter is marked on the package. If the symbol

is marked on

the equipment, consult the documentation for further information.

Safety requirements

Misuse will impair the protection of the product. Always adhere to the safety provisions
applicable in the country of use.

Do not perform any maintenance operation with the power on. Do not let water or foreign
objects inside the device.

Removal of the PCB from the enclosure voids the warranty. Do not touch the electronic
components directly, as they are sensitive to static electricity.

Connection diagrams can be found in the electrical connections section. The device might
not perform correctly or be damaged if the wrong power supply is connected.

External circuits connected to the equipment should have sufficient insulation rating
according to the environmental conditions and equipment power.

A disconnecting device that is marked as such and easily accessible should be included in
the installation of this product.

Operating conditions

The device should be used both in a non-hazardous area and in a basic electromagnetic
environment, where the latter is defined in EN 61326-1. Avoid strong mechanical shock and
vibrations. Avoid corrosive atmosphere and areas highly contaminated with dust, oil mist,
etc. Keep the instrument away from direct sunlight. A sudden temperature or humidity
change might affect the sensitivity of the sensor.

5

Summary of Contents for E2615-H2S

Page 1: ...Hydrogen Sulfide Transmitter E2615 H2S User Manual...

Page 2: ...5 Product description 6 Safety requirements 6 Operating conditions 6 Installation guidelines 6 Mounting dimensions 8 Electrical connections 9 Operation 10 Maintenance 10 Calibration 10 Delivery set 1...

Page 3: ...described as sweet or sickeningly sweet Odor threshold 0 01 1 5 ppm Note Sense of smell becomes rapidly fatigued and can NOT be relied upon to warn of the continuous presence of H2S Hazards Highly fl...

Page 4: ...plastic wall mount protection class IP65 Indoor enclosure White ivory or black ABS plastic wall mount protection class IP20 Dimensions IP65 H70 W80 D36 mm IP20 H71 W71 D27 mm CE marking According to...

Page 5: ...voids the warranty Do not touch the electronic components directly as they are sensitive to static electricity Connection diagrams can be found in the electrical connections section The device might n...

Page 6: ...ance calibration The aforementioned conditions above will affect the coverage area of the device However the coverage area for a transmitter is usually between 2 5 to 5 meters radius For early leakage...

Page 7: ...th a hydrophobic microporous PTFE filter to protect the sensor from dust dirt and water drops NOTE Never stab or press the filter near its center where the sensor is located since this may damage the...

Page 8: ...f wires with a cross section of 0 2 1 5 mm2 We recommend to strip the wire end by 8 9 mm and use wire end sleeves To connect the wire loosen the screw insert the wire end into the terminal hole and ti...

Page 9: ...the screws The device is ready to use Maintenance Do not perform any maintenance operation with the power on Clean the device with a soft damp cloth Do not use any abrasive cleaning agents Do not imm...

Page 10: ...24 08 2022 Delivery set Transmitter E2615 Mounting accessories 2 screws with plastic dowels Order code for E2615 H2S options E2615 options Order code IP20 enclosure E2615 H2S IP20 IP65 enclosure E261...

Page 11: ...Manufacturer will at its option either repair or replace a product that proves to be defective This warranty is void if the product has been operated in conditions outside ranges specified by the Man...

Reviews: